24
www.barryvox.com
S E C O N D A R Y S E A R C H P H A S E
A N A L O G S E A R C H M O D E
Bracketing method
(secondary search phase)
When you select the A8 level, this is only
shown for the first 3 seconds.
Then the display changes to a single dot
in order to improve the quality of the analog
tones.
Pressing any key returns the full display.
14.3 Analog Search Mode
The analog SEARCH mode provides the
acoustic search as known from earlier
beacons. Victims are located by means of
an audible change in the intensity of the
received signal. For best results,
this search
mode requires intensive user training
.
In order to be able to use the analog
SEARCH mode, you must set the search
mode to “dA” in the configuration. See the
section on “Personal Settings” for more
information.
Once you have enabled your Barryvox
for analog search, you can switch between
analog and digital search at any time by
briefly pressing the MODE key while in the
SEARCH mode.
You must now manually adjust the sensi-
tivity of the receiver by means of the UP
and DOWN keys.
A1 corresponds to the smallest and A8
to the greatest distance from the victim.
The analog
search mode
requires
intensive
training.
Display in the
analog SEARCH
mode (here indi-
cating the second
lowest level of
sensitivity).