14 ENGLISH
For HR2652/HR2653/HR2663
Optional accessory
Attach the chuck adapter to a keyless drill chuck to
which 1/2"-20 size screw can be installed, and then
install them to the tool. When installing it, refer to the
section “Installing or removing drill bit”.
►
Fig.28:
1.
Keyless drill chuck
2.
Chuck adapter
For HR2653T
Use the quick change drill chuck as standard equip-
ment. When installing it, refer to “changing the quick
change chuck for SDS-plus”.
Hold the ring and turn the sleeve counterclockwise to
open the chuck jaws. Place the bit in the chuck as far as
it will go. Hold the ring firmly and turn the sleeve clock
-
wise to tighten the chuck.
►
Fig.29:
1.
Sleeve
2.
Ring
To remove the bit, hold the ring and turn the sleeve
counterclockwise.
Diamond core drilling
NOTICE:
If performing diamond core drilling
operations using “rotation with hammering”
action, the diamond core bit may be damaged.
When performing diamond core drilling opera-
tions, always set the action mode changing knob to
the
position to use “rotation only” action.
Beating dust on the filter
CAUTION:
Do not turn the dial on the dust
case while the dust case is removed from the
dust collection system.
Doing so may cause dust
inhalation.
CAUTION:
Always switch off the tool when
turning the dial on the dust case.
Turning the dial
while the tool is running may result in the loss of
control of the tool.
By beating the dust on the filter inside the dust case,
you can keep the vacuum efficiency and also reduce
the number of times to dispose of the dust.
Turn the dial on the dust case three times after col
-
lecting every 50,000 mm
3
of dust or when you feel the
vacuum performance declined.
NOTE:
50,000 mm
3
of dust equivalents to drilling
10 holes of ø10 mm and 65 mm depth (14 holes of
ø3/8" and 2" depth).
►
Fig.30:
1.
Dust case
2.
Dial
Disposing of dust
CAUTION:
Always be sure that the tool is
switched off and unplugged before carrying out
any work on the tool.
CAUTION:
Be sure to wear dust mask when
disposing of dust.
CAUTION:
Empty the dust case regularly
before the dust case becomes full.
Failure to do so
may decrease the dust collection performance and
cause dust inhalation.
CAUTION:
The performance of dust collection
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide.
Failure to do so may cause dust inhalation.
1.
Remove the dust case while pressing down the
lever of the dust case.
►
Fig.31:
1.
Lever
2.
Open the cover of the dust case.
►
Fig.32:
1.
Cover
3.
Dispose of the dust, and then clean the filter.
►
Fig.33
NOTICE:
When cleaning the filter, do not touch
the filter with brush or similar, or blow com
-
pressed air on the filter. It may damage the filter.
Blow-out bulb
Optional accessory
After drilling the hole, use the blow-out bulb to clean the
dust out of the hole.
►
Fig.34
Using dust cup set
Optional accessory
Fit the dust cup set against the ceiling when operating
the tool.
►
Fig.35
NOTICE:
Do not use the dust cup set when drill-
ing in metal or similar. It may damage the dust
cup set due to the heat produced by small metal
dust or similar.
NOTICE:
Do not install or remove the dust cup
set with the drill bit installed in the tool. It may
damage the dust cup set and cause dust leak.
Summary of Contents for HR2653T
Page 2: ...2 2 1 Fig 1 2 1 Fig 2 1 B A Fig 3 1 1 A B Fig 4 2 1 3 Fig 5 2 1 3 4 Fig 6 1 2 Fig 7 1 Fig 8 ...
Page 3: ...3 1 Fig 9 1 2 Fig 10 1 A Fig 11 1 Fig 12 1 Fig 13 1 2 Fig 14 1 Fig 15 1 2 Fig 16 ...
Page 4: ...4 1 Fig 17 1 2 Fig 18 1 Fig 19 1 Fig 20 1 2 Fig 21 1 Fig 22 1 2 Fig 23 Fig 24 ...
Page 5: ...5 Fig 25 Fig 26 Fig 27 1 2 Fig 28 1 2 Fig 29 2 1 Fig 30 1 Fig 31 1 Fig 32 ...
Page 6: ...6 Fig 33 Fig 34 Fig 35 1 Fig 36 1 2 3 Fig 37 1 2 Fig 38 1 2 Fig 39 ...
Page 7: ...7 1 2 Fig 40 ...
Page 51: ...51 ...