GEN-10P
–
USER MANUAL REV0819
Page
13
of
22
STORAGE
STORAGE WITH FUEL IN TANK
Gasoline fuel can become stale when stored over
30 days
. Stale fuel causes
acid and gum deposits to form in the fuel system or crucial carburettor parts. To
keep fuel fresh:
1. Add a fuel stabiliser liquid additive to fuel.
2. Run engine for a minimum of 2 minutes to allow it to circulate throughout the
engine
WARNING
Fuel and fuel vapour are extremely flammable and
explosive. Fire or explosion from misuse of fuel can
cause severe burns and even death.
FIRE
HAZARD
RUST PREVENTION IN CYLINDERS
1. Remove spark plugs and pour approx. 15ml (1/2oz) of clean engine oil into the
cylinder.
2. Install spark plug and briefly turn the key starter for 1-2 seconds to distribute oil.
DO
NOT
start engine at this time.
3. Slowly pull the recoil starter 2-3 times to distribute and coat the cylinder bore
with oil.
WARNING
Unintentional sparking can cause fire or electrical shock.
Failure to observe this warning can cause severe property
damage, severe burns and even death.
Disconnect spark plug wire from spark plug and cover tip of
spark plug wire with insulating tape and place wire where it
cannot come in contact with spark plug or generator frame.
WARNING
Certain storage covers can be flammable or can melt in high
temperatures. DO NOT place storage cover over generator
until it has completely cooled.
Summary of Contents for GEN-10P
Page 1: ...10kVA Generator GEN 10P 2x15A Outlets 2x15A 1x20A or 32A 3P Outlets OPERATOR S MANUAL Rev0919...
Page 8: ...GEN 10P USER MANUAL REV0819 Page 6 of 22 SAFETY DECALS 1 2 3 4 5 6 7 8 9 10...
Page 21: ...GEN 10P USER MANUAL REV0819 Page 19 of 22 APPENDIX A WIRING CIRCUIT DIAGRAM 2x15A...
Page 22: ...GEN 10P USER MANUAL REV0819 Page 20 of 22 APPENDIX B WIRING CIRCUIT DIAGRAM 2x15A 1x20A 3P...