DPC-2200 USER MANUAL
Page 23 of 38
GENERAL MAINTENANCE
CLEAN DEBRIS
Daily or before use, clean accumulated debris from cleaning system. Keep the
unit clean at all times. Keep area around and behind muffler free from any
combustible debris. Inspect cooling air slots and openings on the pressure
cleaner. These openings must be kept clean and unobstructed.
System parts should be kept clean to reduce the risk of overheating and ignition
of accumulated debris.
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt, oil, etc.
Use a vacuum cleaner to pick up loose dirt and debris.
CHECK AND CLEAN INLET FILTER
Examine the inlet water filter on the pump after every use and clean it if the screen
is clogged or replace immediately if screen is damaged.
CHECK HIGH PRESSURE HOSE
The high-pressure hose can develop leaks from wear, kinking, or abuse. Inspect
the hose each time before using it. Check for cuts, leaks, abrasions or bulging of
cover, damage or movement of couplings. If any of these conditions exist, replace
the hose immediately.
WARNING
The high-pressure stream of water that this
equipment produces can cut through skin and its
underlying tissues, leading to serious injury and
possible amputation.
NEVER
repair high pressure hose. Replace it.
Replacement hose rating
MUST
exceed
maximum pressure rating of unit.
NOTE:
IMPROPER
treatment of pressure cleaner can damage it and shorten
its life.
DO NOT
spray any objects through cooling slots.