Card Reader Connection

 

J5 

SER+ 
SER-

 

When  the  button  and  remote  control  are  connected  to  this  port,  the 

turnstile switches to free mode.

 

J5 

GIR+ 
GIR- 

This  port  must  be  operated  with  pushbutton  or  relay  output.  Max.  1 

second  is  recommended.  When  a  signal  is  received  from  J5,  the 

turnstile  opens  in  the  direction  of  entry.  (If  the  set  mode  input 

direction is set to controlled pass).

 

J5 

CIK+ 

CIK- 

This  port  must  be  operated  with  pushbutton  or  relay  output.  Max.  1 

second  is  recommended.  When  a  signal  is  received  from  J5,  the 

turnstile  opens  in  the  exit  direction.  (If  the  set  mode  output  direction 

is set to controlled pass).

 

 
 

Mode Settings 

SW-3

 

(MODE)

 

When  the  Mode  button  is  touched,  the  LED  5  lights  up.  The  card  is  in 

program  mode.  Press  the  button  of  the  desired  direction  to  make  the 

program.

 

SW-1 

(GİRİŞ) 

After  pressing  the  MODE  button,  the  card  will  switch  to  'LOCKED', 

'CONTROLLED',  'FREE'  modes  each  time  this  switch  is  touched.  After 

selecting  the  desired  mode,  press  MODE  SW-3  again.  LED  5  is  off.  The 

tourniquet is then programmed to the desired mode. 

SW-2 

(ÇIKIŞ) 

Each  time  the  switch  is  pressed,  the  card  will  switch  to  'LOCKED', 

'CONTROLLED',  and  'FREE'  modes,  respectively.  After  selecting  the  desired 

mode,  press  MODE  SW-3  again.  LED  5  is  off.  The  tourniquet  is  then 

programmed to the desired mode.

 

 

 

The  preferred  power  source  for  the  turnstile  is  25W,  24V,  1.1A.  A  power 

supply below these values should not be used.

 

L N Port: 220AC V is applied. A grounding line is drawn from the ground 

symbol to the turnstile body. 

-V +V Port: Connect to V+(+) to V- (-) towards J1 socket of BM32 control 

board.

 

 

 

 

 

 

 

 

 

Fullheight turnstiles operate with 220VAC voltage. Power cable which will be used in turnstiles must be  min. 
3 x 1.5 TTR. Power cable and ground connections points must be screwed in tightly.  

 

 

BM32 Control Board 

Power Supply 

Connections 

Summary of Contents for T2500D DOUBLE 4

Page 1: ...LLHEIGHT TURNSTILE USER MANUAL T2500D SINGLE 3 ARMED T2500D SINGLE 4 ARMED T2500D DOUBLE 3 ARMED T2500D DOUBLE 4 ARMED T2500K SINGLE 3 ARMED T2500K SINGLE 4 ARMED T2500K DOUBLE 3 ARMED T2500K DOUBLE 4...

Page 2: ...Contents Attention Technical Specificitaion Physical Specifications Installation and Mounting Connections Maintenance Instruction Documents 3 3 4 6 7 8 9...

Page 3: ...ater directly on the turnstile Contact your authorized service center for turnstile maintenance and repair Products must be in their original packaging when transported Pay attention to the instructio...

Page 4: ...Physical Specification Dimensions are given in mm 4 T2500D SINGLE 3 ARMED T2500D DOUBLE 3 ARMED T2500D DOUBLE 4 ARMED T2500D SINGLE 4 ARMED...

Page 5: ...Dimensions are given in mm 5 T2500K SINGLE 3 ARMED T2500K SINGLE 4 ARMED T2500K DOUBLE 3 ARMED T2500K DOUBLE 4 ARMED...

Page 6: ...Drill 8 cm deeped marked mounting holes by 12mm drill top as using drill and hilt Fix the steel anchors to the drilled holes If the ground is not strong fix the steel anchors using chemical soil mixt...

Page 7: ...pressing the MODE button the card will switch to LOCKED CONTROLLED FREE modes each time this switch is touched After selecting the desired mode press MODE SW 3 again LED 5 is off The tourniquet is th...

Page 8: ...ol Equipments and Rotation Parts The mechanism is rotated one turn to see if it is working properly rotating parts Central Control Element Tubes and working surfaces The problematic parts are checked...

Page 9: ...Documents 9...

Reviews: