background image

 

 

Version: 1.05, 05.10.18 

  

15 

10

 

EU Declaration of Conformity 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EU  Declaration of Conform ity  

in accordance with the Low  Voltage Directive (LVD) 2014/35/EU  

 

Manufactorer: 

Lightpower G m bH  

 

An der Talle 24 -28  

 

D-33102 Paderborn 

 
Authorized person for the issuance  
of the declaration  of conform ity : 

Andr

é

 Raude 

 

U lm enweg 2  

 

32832 Augustdorf 

 
 

Product 
m odel 

Product descriptio n  

4001408 

DMX -Merger 2 in1 , X LR5 

4001733 

DMX -Merger 3in1 , X LR5 

4002164 

DMX -Merger 3in1 , RJ45 

 
 
We hereby certify that the above-nam ed pro duct(s),

 

as we p ut the execution 

into circulatio n, is/are conform  with  the regulations of the fo llow ing EU -
directives:   
 
Low Voltage Directive (LVD) 2014/35/EU   
(EMC) Directive 2014/30/EU   
RoHS Directive (2011/65/EU ) 
 
Applied harm onized standards: 
 
EN 60204 -1 
91/263/EWG ; 92/31/EWG ; 93/68/EWG  
 
The ob ject of the declaration described abov e is in  conform ity with the relevant 
U nio n harm o nisatio n leg islation. Any m od ification of this prod uct(s) with out 
confirm ation shall auto m atically ann ul this d eclaration. 
 

 

 

 

 

 

 

 

 

 

 

 

          

 

Paderborn, 28th Aug ust, 2018   

 

Andr

é

 Raude 

Summary of Contents for 4001733

Page 1: ...Major DMX Merger 3in1 User Manual...

Page 2: ...rm nor by photos or electronic media Delivery options and all technical specifications are subject to change without notification We do not assume liability for any incorrect information in this docum...

Page 3: ...llation 4 2 Standard Operating Mode Display 5 3 Termination Switch 6 4 Configuration 7 5 Submenu 1 Output 9 6 Submenu 2 Merge Modus 11 7 Submenu 3 4 5 DMX insert address for input A B C 12 8 Submenu 7...

Page 4: ...d LEDs on the front of the device flash briefly from left to right during the self test Then the yellow RDM LED for input B flashes to indicate the main version number of the firmware currently loaded...

Page 5: ...e front for visualizing the main device function for each input The status of each input where a valid DMX signal is present is indicated by slow flashing of the assigned green DMX LED If RDM communic...

Page 6: ...MINATION which allows the user to simply connect the terminating resistor 120 Ohm in position I on the right required at the end of a DMX line However if the respective signal line runs further from t...

Page 7: ...enus are also lost After the first press of the left MENU key the first submenu is proposed for selection Use the two UP DOWN keys to the right of the display to scroll to the desired submenu item in...

Page 8: ...NU ESC key automatically returns the unit to the STANDARD OPERATING MODE To enter the desired submenu press the OK key at the bottom left Please notice Even after entering the menu level the device co...

Page 9: ...cancel and return to the main menu with MENU ESC key The repetition rates of the DMX output signal are approximate only Also the output signal is not simply slowed down by a waiting time at the end of...

Page 10: ...te BREAK LENGTH MAB MARK AFTER BREAK MBS MARK BETWEEN SLOTS MBB MARK BEFORE BREAK PERIOD TIME REFRESH RATE 44 Hz 92 s 12 s 44 s 22 7 ms 44 0 Hz 33 Hz 176 s 24 s 16 s 176 s 31 1 ms 32 1 Hz 22 Hz 220 s...

Page 11: ...In practice this allows parallel operation while simultaneously ensuring a possible minimum level for each input channel safety function emergency light through light etc MODE 1 LoTP display shows LO...

Page 12: ...rge lighting console controls at input A the entire DMX area of one event location A second smaller lighting console has access to the lighting circuits of the foyer at input B from DMX 301 but via it...

Page 13: ...Y PERM ON If it is set to PERMANENT ON or DISPLAY AUTO OFF if it switches AUTOMATICALLY OFF If the AUTO OFF function is activated the display is switched off after a period of approx 30 seconds withou...

Page 14: ...perating device does not have a separate power switch Also any held channels in HTP or LoTP mode of a source that has meanwhile been switched off or staked out are reset Electrical data Approvals 2006...

Page 15: ...n1 X LR5 4002164 DMX Merger 3in1 RJ45 We hereby certify that the above nam ed product s as we put the execution into circulation is are conform with the regulations of the following EU directives Low...

Page 16: ...16 Version 1 05 05 10 18...

Reviews: