background image

 

 

Version: 1.05, 05.10.18 

  

11 

6

 

Submenu 2 

 Merge Modus 

 
After entering the Submenu 2 (MERGE MODE), the following display 
appears: 
 

MERGING-MODE: 

HTP 

Mode 1, 

or

 

MERGING-MODE: 

LOW 

Mode 2, 

or

 

MERGING-MODE: 

LTP 

Mode 3 

 

Changes, selections and cancel are performing as described in the 
chapter "submenu 1" above. 
This configuration can be used to set the standard operating mode of the 
device. There are currently 3 different types of functions (MODI) 
available: 
 

MODE 0:

 

HTP 

 HIGHEST TAKES PRECEDENCE  

This is the most frequently used mode in practice. Each output channel 
receives the value which is the highest of all three inputs. Thus each 
input (in each channel) can increase the value up to 100 percent, but a 
complete dark regulation is only possible if all input values = 0. In 
practice, this allows parallel operation, while simultaneously ensuring a 
possible minimum level for each input channel (safety function, 
emergency light, through-light, etc.). 

 
MODE 1: LoTP

 

(display shows: LOW) 

  LOWEST TAKES 

PRECEDENCE  
The opposite is of course also possible. This also allows parallel 
operation. In this case maximum values can be specified for individual or 
all channels, which then cannot be exceeded. 
Applications could be for example lamp protection, energy saving as well 
as the protection of sensitive art objects from excessive lighting intensity. 

 
MODE 2: LTP

 - LATEST TAKES PRECEDENCE  

The channel value that was last modified on all 3 inputs always passes to 
the output channel. This allows parallel operation WITHOUT a single 
input being able to permanently block or restrict the values.  This means 
that every source has the possibility of sole control. Unfortunately, 
lighting jumps may occasionally occur during transfer in this mode.  

Summary of Contents for 4001733

Page 1: ...Major DMX Merger 3in1 User Manual...

Page 2: ...rm nor by photos or electronic media Delivery options and all technical specifications are subject to change without notification We do not assume liability for any incorrect information in this docum...

Page 3: ...llation 4 2 Standard Operating Mode Display 5 3 Termination Switch 6 4 Configuration 7 5 Submenu 1 Output 9 6 Submenu 2 Merge Modus 11 7 Submenu 3 4 5 DMX insert address for input A B C 12 8 Submenu 7...

Page 4: ...d LEDs on the front of the device flash briefly from left to right during the self test Then the yellow RDM LED for input B flashes to indicate the main version number of the firmware currently loaded...

Page 5: ...e front for visualizing the main device function for each input The status of each input where a valid DMX signal is present is indicated by slow flashing of the assigned green DMX LED If RDM communic...

Page 6: ...MINATION which allows the user to simply connect the terminating resistor 120 Ohm in position I on the right required at the end of a DMX line However if the respective signal line runs further from t...

Page 7: ...enus are also lost After the first press of the left MENU key the first submenu is proposed for selection Use the two UP DOWN keys to the right of the display to scroll to the desired submenu item in...

Page 8: ...NU ESC key automatically returns the unit to the STANDARD OPERATING MODE To enter the desired submenu press the OK key at the bottom left Please notice Even after entering the menu level the device co...

Page 9: ...cancel and return to the main menu with MENU ESC key The repetition rates of the DMX output signal are approximate only Also the output signal is not simply slowed down by a waiting time at the end of...

Page 10: ...te BREAK LENGTH MAB MARK AFTER BREAK MBS MARK BETWEEN SLOTS MBB MARK BEFORE BREAK PERIOD TIME REFRESH RATE 44 Hz 92 s 12 s 44 s 22 7 ms 44 0 Hz 33 Hz 176 s 24 s 16 s 176 s 31 1 ms 32 1 Hz 22 Hz 220 s...

Page 11: ...In practice this allows parallel operation while simultaneously ensuring a possible minimum level for each input channel safety function emergency light through light etc MODE 1 LoTP display shows LO...

Page 12: ...rge lighting console controls at input A the entire DMX area of one event location A second smaller lighting console has access to the lighting circuits of the foyer at input B from DMX 301 but via it...

Page 13: ...Y PERM ON If it is set to PERMANENT ON or DISPLAY AUTO OFF if it switches AUTOMATICALLY OFF If the AUTO OFF function is activated the display is switched off after a period of approx 30 seconds withou...

Page 14: ...perating device does not have a separate power switch Also any held channels in HTP or LoTP mode of a source that has meanwhile been switched off or staked out are reset Electrical data Approvals 2006...

Page 15: ...n1 X LR5 4002164 DMX Merger 3in1 RJ45 We hereby certify that the above nam ed product s as we put the execution into circulation is are conform with the regulations of the following EU directives Low...

Page 16: ...16 Version 1 05 05 10 18...