background image

Range 

Resolution 

Accuracy 

600μA 

0.1μA 

6000μA 

1μA 

60mA 

10μA 

600mA 

100μA 

±(1.2% of rdg + 2 digits) 

6A 

1mA 

10A 

10mA 

±(2.0% of rdg + 3 digits) 

Range 

Resolution 

Accuracy 

6V 

1mV 

60V 

10mV 

±(1.0% of rdg + 3 digits) 

600V 

100mV 

±(1.5% of rdg + 3 digits) 

Range 

Resolution 

Accuracy 

600mV 

0.1mV 

6V 

1mV 

60V 

10mV 

±(0.5% of rdg + 2 digits) 

600V 

100mV 

±(0.8% of rdg + 2 digits) 

MT873

Digital Multimeter

Introduction

The MT873 multimeter is a slim sized, portable, robust drop proof digital multimeter. The 
MT873 has a 6000 count digit LCD monitor with large 25mm digits that offer clear and 
easy reading. The circuitry design is centred on large-scale IC A/D converters in 
conjunction with an over-load protection circuit, the meters offers excellent performance 
and is ideal for a  versatile digital multimeter.

The meters can be used to measure DC & AC voltage, DC & AC current, resistance, 
capacitor, frequency, duty cycle, temperature, Non Contact AC Voltage (NCV) detection, 
diode test and audible continuity. If the equipment is used in a manner not specified by 
the manufacturer, the protection provided by the equipment may be impaired.

This Equipment Conforms to UL STD. 61010-1, 61010-2-030 and 61010-2-033; Certified to 
CSA STD. C22.2 NO. 61010-1, 61010-2-030 and 61010-2-033.

1

CDS

 sensor: The CDS sensor can reaction to the ambient brightness  range, then 

 

automatically control the LCD backlight to lighten or go out.

2. 

NCV detection area: Non Contact AC Voltage (NCV) detection area.

3. 

NCV red light: Non Contact AC Voltage (NCV) detection red light.

4. 

NCV green light: Non Contact AC Voltage (NCV) detection green light.

5. 

LCD display: 6000 counts digit, full function symbol display.

6. 

SELECT

 key: This key work on the “          ” range, press the key to c hoose resistance, 

.

 

diode or continuity test, on the voltage or current  range, change to DC or AC, on the

 

 

°C/°F 

range, change to °C or °F test; I f press a

  nd hold SELECT key to power on, “Auto 

 

Power Off ” function will  be disabled.

7. 

RANGE

 Key: Press the “

RANGE

” key, the meter enters manual range  mode, press it 

 

more than 2 seconds again, return to auto mode.

8. 

HOLD

 key: Press the “

HOLD

” key to lock display value, and the “

DH

” sign w

  ill appear 

 

on the display, press it again to exit.

9. 

REL

 Key: Press the “

REL

” key, the meter enters relative measuring mode,  “

REL

” is 

 

displayed on the LCD and the present reading becomes the  reference value and 

 

displayed on the display. Relative measurement  REL    =measurement value-Reference 

 

value.  Press it again to exit.

10. 

Hz/%

 Key: On “ACV/ACA” or “Hz” range, press the “

Hz/%

” key, you can   choose the

 

Frequency 

or 

Duty Cycle

 measurement.

11. 

Rotary Switch

: Use this switch to select functions and ranges.

12. 

COM

: COM and Temperature “

-

” Input Jack.

13. 

10A

: 10A Input Jack

14. 

VΩmA

: V/μAmA/Hz/

Ω          /       

and Temperature “

+

” Input Jack

15.  Meter casing
16.  Protective casing

Safety Information

1. 

The meter is designed according to IEC-61010 concerning e

  lectronic m

  easuring 

 

instruments with an over-voltage category  600V (CAT II) or  300V (CAT III) and 

 

pollution 2.

2. 

Follow all safety and operating instructions to ensure that the m

  eter is u

  sed safely and 

 

is kept in good operating condition.

3. 

Safety symbols:

 

 

Important safety information, refer to the operating manual.

 

 

Dangerous voltage may be presence

 

 

Double insulation (protection Class II)

Special Cautions for Operation

1. 

The meters can be safe only according to standard procedures w

  hen used i n conjunction 

 

with the supplied test leads. Please  replace damaged test  leads with the same 

 

specifications.

2. 

To avoid risk of electric shock, do not use the meter if the casing h

  as been o

  pened.

3. 

The range switch should be in the right position before making a m

  easurement.

4. 

To avoid electric shock and damaging the instrument, the input s ignals must n

  ot exceed 

 

the specified limits.

5. 

When measuring TV set or switched power, attention should be p

  aid to the p

  ossible pulses 

 

that may cause damage to the circuitry.

6. 

Range switch position must not be changed at random during m

   easurement.

7. 

Take caution against shock in the course of measuring voltage h

  igher than D

  C 60V & AC 

 

30V.

8. 

Protection fuse should be replaced only with same type and same s pecification.

9. 

After using the meter, set function switch to OFF to save battery p

  ower.

10.  If the meter is not used for a long time, take out battery to avoid d

  amage b

  y battery 

 

leakage.

General Specifications

1

Max Voltage between input terminal and Earth: CAT II  600V or  CAT III 300V

2. 

Over-range Indication: display “OL” for the significant digit.

3. 

Automatic display of negative polarity “

-

”.

4. 

Low Battery Indication: “      ” displayed.

.

5. 

Max LCD display: 6000 counts digit.

6. 

Auto range & Manual range control

7. 

Auto Power Off: When measurement exceeds 15 minutes without c hanging t he mode and 

 

pressing key, the meter will switch to  standby mode. Press  any key to exit standby mode. 

 

When switching the meter back on, press  and hold the 

SELECT

 key to  disable auto power 

 

off.

8. 

Auto LCD backlight

9. 

Fuse protection: 600mA/600V Fast Fuse, 10A/600V Fast Fuse

10.  Power supply: 9V 6F22 battery
11.  Operating Temp.: 0

 to 40

 (relative humidity <85%)

°C

°C

12.  Storage Temp.: -10

 to 50

 (relative humidity <85%)

°C

°C

13.  Guaranteed precision Temp.: 23±5

 (relative humidity <70%)

°C

14.  Dimension: 150 x 100 x 36mm
15.  Weight: approx. 250g (including battery)

Testing Specifications

Accuracy is specified for a period of year after calibration and at 18

 to 28

 (64

 to 82

°C

°C

°F

°F

with relative humidity to 70%.

DC Voltage

* Impedance: 10MΩ, More than 100MΩ on 600mV range 
* Overload protection: 600V DC or AC RMS 

AC Voltage (True RMS) 

* Impedance: 10MΩ 
* Overload protection: 600V DC or AC RMS 
* Frequency Range: 40 to 400Hz 

DC Current 

* Overload protection: 600mA/600V Fast Fuse, 10A/600V Fast Fuse, 
   10A up to 10 seconds 

Panel Layout

Resistance 

Range 

Resolution 

Accuracy 

600Ω 

0.1Ω 

±(1.0% of rdg + 3 digits) 

6kΩ 

1Ω 

60kΩ 

10Ω 

600kΩ 

100Ω 

6MΩ 

1kΩ 

±(1.0% of rdg + 2 digits) 

60MΩ 

10kΩ 

±(1.5% of rdg + 3 digits) 

Range 

Resolution 

Accuracy 

600μA 

0.1μA 

6000μA 

1μA 

60mA 

10μA 

600mA 

100μA 

±(1.5% of rdg + 3 digits) 

6A 

1mA 

10A 

10mA 

±(2.5% of rdg + 5 digits) 

AC Current (True RMS) 

* Overload protection: 600mA/600V Fast Fuse, 10A/600V Fast Fuse, 
   10A up to 10 seconds 
* Frequency Range: 40 to 400Hz 

* Overload protection: 600V DC or AC RMS

1

4

9

10

14

15

16

2

3

5

6

7

8

11

12
13

Reviews: