8
5.6. AC/DC Voltage Measurements
1. Set the rotatory function switch to the
V ~
position.
2. Press the
MODE
button to select
AC
or
DC
voltage.
The AC “ ” or DC “ ” symbol will appear on the
~
LCD display.
3. Insert the black test lead into the
COM
input jack
and the red test lead into the
V
input jack.
4. Touch the test lead probes to the circuit under test. If
measuring DC voltage, touch the red test lead to the
positive side of the circuit and the black test lead to
the negative side of the circuit.
Observe all safety precautions when working on live circuits.
!
WARNING:
5.7. Frequency And % Duty Cycle Measurements
1. Set the rotary function switch to the
position.
HZ %
2. Press the
button to select frequency or
MODE
%
duty cycle. The “
” or “
” symbol will appear on
Hz
%
the LCD display.
3. Insert the black test lead into the
input jack
COM
and the red test lead into the input jack.
V
4. Touch the test lead probes to the circuit under test.
5. Read the frequency or % duty cycle on the LCD
display.
5.8. AC Current Measurements
1. Set the rotary function switch to the
10A~
position.
2. Insert the black test lead into the
COM
input jack
and the red test lead into the
10A
input jack.
3. Remove power from the circuit under test, then open
up the circuit at the point where you wish to
measure current.
4. Touch the test lead probes in series with the circuit
being measured.
5. Apply power to the circuit.
6. Read the current on the LCD display.
Observe all safety precautions when working on live voltages.
Do not measure frequency or duty cycle on circuits that exceed
600V.
!
WARNING:
Observe all safety precautions when working on live circuits. Do
not measure current on circuits that exceed 250V. Measurements
in the 10A range should be limited to 30 seconds maximum every
15 minutes. Max voltage 600V.
!
WARNING:
Summary of Contents for MT25
Page 1: ...25 YEAR SPECIAL EDITION MT25 600V AC DC MULTIMETER INSTRUCTION MANUAL ...
Page 2: ...2 ...
Page 15: ...15 ...