Range
Resolution
Accuracy
2000Hz
1Hz
±1.5% of rdg ± 5 dgts
Frequency
Sensitivity: 200mV ~ 10V RMS
Overload Protection: 250V DC or AC RMS
Temperature
Sensor: Type-K Thermocouple
Overload Protection: 250V DC or AC RMS
Diode Test
Test Current: 1mA typical
Open Circuit Voltage: 2.8V DC typical
Overload Protection: 250V DC or AC RMS
Audible Continuity
Audible threshold: less than 50Ω; test current <0.3mA
Overload Protection: 250V DC or AC RMS
4. Operation
Warning:
Risk of electrocution. High voltage circuits, both AC and DC
are very dangerous and should be measured with great
care.
If “1" appears in the display during a measurement, the value exceeds
the range you have selected. Change to a higher range.
Note:
On some low AC and DC voltage ranges, with the test leads not
connected to a device, the display may show a random,
changing reading. This is normal and is caused by the high-
input sensitivity. The reading will stabilise and give proper
measurements when connected to a circuit.
Range
Resolution
Accuracy
-20°C to 760°C
-4°F to 1400°F
1°C
1°F
±
3% of rdg ±5°C/9°F
8
Summary of Contents for MT1883
Page 1: ...MT1883 Manual Ranging Multimeter INSTRUCTION MANUAL...