AC Current

Overload Protection: 0.2A/250V and 20A/250V fuse.
Frequency Range: 50 to 400Hz
Maximum Input: 200mA DC or 200mA AC RMS on mA ranges, 20A DC 
or AC RMS on 20A range.

Resistance

Input Protection: 250V DC or 250V AC RMS

Capacitance

Input Protection: 250V DC or 250V AC RMS.

Range 

Resolution  

Accuracy

 

2.000mA  

1uA

200.0mA

 

100uA

 

20.00A  

10mA  

±2.0% of rdg ± 3 dgts

±1.2% of rdg ± 3 dgts

±3.0% of rdg ± 10 dgts

 Range

Resolution  

Accuracy

 

200.0Ω

0.1Ω

2.000kΩ

1Ω

20.00kΩ

10Ω

200.0kΩ

100Ω

2.000MΩ

1kΩ

20.00MΩ

10kΩ

±1.0% of rdg ± 2 dgts

±1.0% of rdg ± 4 dgts

±1.2% of rdg ± 2 dgts

±2.0% of rdg ± 5 dgts

Range 

Resolution

 

Accuracy  

2.000nF

1pF  

20.00nF

10pF  

200.0nF

0.1nF  

 

2.000uF

1nF  

200.0uF

0.1uF

 

 

±4.0% of rdg ± 70 dgts

±4.0% of rdg ± 3 dgts

≥21uF

≤20uF

±4.0% of rdg ± 15 dgts
unspecified

7

Summary of Contents for MT1883

Page 1: ...MT1883 Manual Ranging Multimeter INSTRUCTION MANUAL...

Page 2: ...urement 9 4 3 AC Voltage Measurement 9 4 4 DC Current Measurement 10 4 5 AC Current Measurement 10 4 6 Resistance Measurement 11 4 7 Continuity Check 11 4 8 Diode Test 11 4 9 Frequency Measurement 12...

Page 3: ...t under test before cutting unsoldering or breaking the circuit Small amounts of current can be dangerous Use caution when working above 60V DC or 30C AC RMS such voltages pose a shock hazard When usi...

Page 4: ...on which if not avoided may result in damage to the product This symbol advises the user that the terminal s so marked must not be connected to a circuit point at which the voltage with respect to ear...

Page 5: ...lay with function indication Polarity Automatic negative polarity indication Overrange OL mark indication Low Battery Indication The is displayed when the battery voltage drops below the operating lev...

Page 6: ...50V and 20A 250V fuse Maximum Input 200mA DC or 200mA AC RMS on mA ranges 20A DC or AC RMS on 20A range Range Resolution Accuracy 200 0mV 0 1mV 2 000V 1mV 20 00V 10mV 200 0V 100mV 1000V 1V 0 5 of rdg...

Page 7: ...250V AC RMS Range Resolution Accuracy 2 000mA 1uA 200 0mA 100uA 20 00A 10mA 2 0 of rdg 3 dgts 1 2 of rdg 3 dgts 3 0 of rdg 10 dgts Range Resolution Accuracy 200 0 0 1 2 000k 1 20 00k 10 200 0k 100 2 0...

Page 8: ...RMS 4 Operation Warning Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care If 1 appears in the display during a measurement the value...

Page 9: ...and value If the polarity is reverse the display will show minus before the value 4 3 AC Voltage Measurements Warning Risk of electrocution The probe tips may not be long enough to contact the live p...

Page 10: ...r to the circuit 7 Read the current on the display The display will indicate the proper decimal point value 4 5 AC Current Measurement Warning To avoid electric shock do not measure AC current on any...

Page 11: ...the display The display will indicate the proper decimal point value 4 7 Continuity Check Warning To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set...

Page 12: ...y The digital reading will indicate the proper decimal point value 4 10 Capacitance Measurements Warning To avoid electric shock disconnect power to the unit under test and discharge all capacitors be...

Page 13: ...omes at or drops below the operating voltage BAT will appear in the right hand side of the LCD display The battery should be replaced 2 Follow instructions for installing the battery See the battery i...

Page 14: ...y item under test 2 Open the back cover by loosening the screw on the back cover using a phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse...

Page 15: ......

Page 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: