19
AC Current
(Auto-ranging)
Range
Resolution
Accuracy
400.0uA
0.1uA
+1.2% of rdg + 6 digits
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
+1.5% of rdg +
6
digits
10A
10mA
+2.0% of rdg + 6 digits
All AC Current ranges are specified from 5% of range to 100%
of range
Overload Protection: FF500mA/1000V and F10A/1000V Fuse.
AC Response: 50 Hz to 400 Hz
Maximum Input:
4000uA ac rms on uA
500mA ac rms on mA
10A ac rms on 10A range
Resistance [
Ω] (Auto-ranging)
Range
Resolution
Accuracy
4
00.0Ω
0.1Ω
+1.2% of rdg + 4 digits
4
.000kΩ
1Ω
+1.2% of rdg + 2 digits
4
0.00kΩ
10Ω
4
00.0kΩ
100Ω
4
.000MΩ
1kΩ
+1.5% of rdg +8digits
4
0.00MΩ
10kΩ
Input Protection: 1000V dc or 750V ac rms.
Capacitance
(Auto-ranging)
Range
Resolution
Accuracy
40.00nF
10pF
+5.0% of rdg + 20 dgts
400.0nF
0.1nF
+3.0% of rdg + 5 dgts
4.000uF
1nF
40.00uF
10nF
400.0uF
0.1uF
4000uF
1 uF
+5.0% of rdg + 10 dgts
Input Protection: 1000V dc or 750V ac rms.