1. SAFETY WARNINGS

The following safety information must be observed to    
insure maximum personal safety during the operation          
of this meter:

•  Measurements beyond the maximum selected range must not be 

attempted.

•  Extreme care must be taken when measuring above 50 V, especially on 

live bus-bars.

•  To measure voltage, the instrument must not be switched to a current 

or resistance range, or to the diode check or buzzer position.

•  Circuits must be de-energized and isolated before carrying out 

resistance tests.

•  The rotary selector switch must only be turned after removing test 

connections.

•  External voltages must be disconnected from the instrument before 

removing the battery.

•  Test leads and prods must be in good order, clean, and with no broken 

or cracked insulation.

•  UK Safety Authorities recommend the use of fused test leads when 

measuring voltage on high energy systems.

•  Replacement fuses must be of the correct type and rating.
•  The instrument must not be used if any part of it isdamaged.
•  Warnings and precautions must be read and understood before an 

instrument is used. They must be observed during the operation of this 
instrument.

 

2. SAFETY SYMBOLS

Caution: refer to accompanying notes.

This symbol indicates that the operator must refer to an 
explanation in the Operating Instructions to avoid personal 
injury or damage to the meter.

Caution: risk of electric shock

This WARNING symbol indicates a potentially hazardous 
situation, which if not avoided, could result in death or 
serious injury.
This 

CAUTION

 symbol indicates a potentially hazardous 

situation, which if not avoided, may result damage to the 
product.

 

 

Symbols used on this instrument are:

Summary of Contents for MT1877IV

Page 1: ...INSTRUCTION MANUAL 1000V AC DC TRMS MULTIMETER IV MT1877...

Page 2: ...2...

Page 3: ...13 Capacitance Measurement 9 3 14 Frequency Measurement 9 3 15 Non Contact Voltage NCV 9 4 Specifications 10 4 1 Non Contact Voltage NCV 11 4 2 DC Voltage Auto ranging 12 4 3 AC Voltage Auto ranging 1...

Page 4: ...d with no broken or cracked insulation UK Safety Authorities recommend the use of fused test leads when measuring voltage on high energy systems Replacement fuses must be of the correct type and ratin...

Page 5: ...when connected to a circuit This symbol advises the user that the terminal s so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds in this case...

Page 6: ...ou want 3 Press and hold the RANGE button for 2 seconds to exit the Manual Ranging mode and return to Auto Ranging 3 5 REL BUTTON REL Key is the relative value measurement key that acts with trigger E...

Page 7: ...MEASUREMENT 1 Insert the black test lead plug into the negative COM socket 2 For current measurements up to 10A set the function switch to the A position and insert the red test lead plug into the 10...

Page 8: ...resistance is less than 50 the audible signal will sound The display will also show the actual resistance in ohms 3 12 DIODE TEST 1 Set the function switch to the position 2 Insert the black test lea...

Page 9: ...tch to the Hz position 2 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack 3 Touch the test probe tips to the circuit under...

Page 10: ...ctor 3 at full scale up to 500V decreasing linearly to 1 5 at 1000V NOTE These meters meet CAT III and CAT IV IEC 61010 standards The IEC 61010 safety standard defines four over voltage categories CAT...

Page 11: ...after approx 15 minutes of inactivity To disable the auto power off feature hold down the MODE Button and turn the meter on Operating environment 0 C to 50 C 32 F to 122 F at 70 relative humidity Sto...

Page 12: ...andwidth 50Hz to 1 kHz Sine 50Hz to 60Hz All wave Maximum Input 1000V DC or 1000V AC RMS Range Resolution Accuracy 400 0mV 0 1mV 4 000V 1mV 40 00V 10mV 0 8 of rdg 8 digits 400 0V 100mV 1000V 1V 4 3 AC...

Page 13: ...A 4 000A 1mA 2 0 of rdg 3digits 10A 10mA 4 5 AC CURRENT AUTO RANGING Range Resolution Accuracy 99 99nF 10pF 5 0 of rdg 20 digits 999 9nF 0 1nF 9 999uF 1nF 4 0 of rdg 5 digits 99 99uF 10nF 999 9uF 0 1u...

Page 14: ...idth 5Hz 150kHz Overload protection 250V DC or AC RMS Range Resolution Accuracy 10 00 1kHz 0 01Hz 0 5 of rdg 5 digits 4 10 FREQUENCY ELECTRICAL Sensitivity ACV Range 6 Range 6000 600 0mN 10 00A Range...

Page 15: ...test 2 Open the fuse door by loosening the screw on the door using a Phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse into the holder 5...

Page 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: