5.000Hz
50.00Hz
500.0Hz
5.000kHz

±

(1.2% ± 3 digits)

Frequency
(Auto-ranging)

Range

Accuracy 

Function

Resolution

0.001Hz
0.01Hz
0.1Hz
1Hz

Sensitivity: >0.5V RMS while ≤1MHz,
Sensitivity: >3V RMS while >1MHz
Input Protection: 250V DC or 250V AC RMS

±

(1.5% ± 4 digits)

50.00kHz
500.0kHz

10Hz
100Hz

10.00MHz

1kHz

Range

Test current 1.4mA DC and open circuit voltage 2.8V DC

Built in Buzzer will be sound if the circuit resistance is less 
than 50

Ω

Function

Diode Test

Overload Protection: max 600V DC or 600V AC RMS

Continuity

6. Operating Instructions
6.1. Measuring Sound Level

Set the function switch to the “dB” position.

Move the meter to face the microphone to a sound source in a 
horizontal position.

The C-weighting curve is nearly uniform over the frequency range 
from 30 to 10,000Hz, thus giving an indication of overall Sound 
level.

The Fast response is suitable to measure shout bursts and peak 
values from sound source.

The sound level will be displayed.

Note: 

Strong wind (over 10m/sec.) striking the microphone can cause 

misreading for measurement in windy locations, a windscreen 
should be used in front of microphone.

6.2. Measuring Humidity

Humidity Measurement for indoor.

Set the function switch to the ON position.

Move the meter and place in the room.

Read the %RH on the display after about two hours.

9

Summary of Contents for MT1875

Page 1: ...MT1875 6 in 1 Environmental Multimeter INSTRUCTION MANUAL...

Page 2: ...perating Instructions 9 6 1 Measuring Sound Level 9 6 2 Measuring Humidity 9 6 3 Measuring Light 10 6 4 Measuring Temperature 11 6 5 Measuring DC Voltage 11 6 6 Measuring AC Voltage 12 6 7 Measuring D...

Page 3: ...uctor sensor and Type K thermocouple The digital multimeter performs AC DC Voltage AC DC Current Resistance measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter h...

Page 4: ...ctric condenser microphone inside 9 Photo Detector Long life silicon photo diode inside 10 Hz button The button at AC DC Voltage measurement and AC DC Current measurement and Hz measurement Function i...

Page 5: ...ructions Press the REL button to store the reading in the display and the REL indicator will appear on the display The display will now indicate the difference between the stored value and the measure...

Page 6: ...ns 170 x 78 x 48mm Weight 335g including holster Accuracy is given at 18 C to 28 C 65 F to 83 F less than 70 RH 5 2 Sound Level Measurement range 35 to 100dB Resolution 0 1dB Frequency Range 30Hz to 1...

Page 7: ...erload Protection 250V DC or AC RMS for 400mV ranges and 250V DC or 250V AC RMS for other ranges 400 0mV 4 000V 40 00V 400 0V 600V 1 4 digits 1 5 4 digits DC Voltage Auto Ranging Range Accuracy Functi...

Page 8: ...load Protection 500mA 660V and 10A 600V Fuse AC Response 50Hz to 400Hz Maximum Input 400mA DC or 400mA AC RMS on uA mA ranges 10A DC or AC RMS on 10A range 1 2 2 digits 1 5 2 digits 400 0 4 000k 40 00...

Page 9: ...ound Level Set the function switch to the dB position Move the meter to face the microphone to a sound source in a horizontal position The C weighting curve is nearly uniform over the frequency range...

Page 10: ...teristic To the detector the applied photo diode with lters makes the spectral sensitivity characteristic almost meet C I E International Commission on Illumination photopia curve V as the following c...

Page 11: ...ed plug to the V Hz CAP C jack Touch the end of the temperature sensor to the area or surface of the object to be measured The display will show the temperature reading value C or F respectively 6 5 M...

Page 12: ...into the uA mA jack For current measurements up to 10A DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicat...

Page 13: ...lack test lead banana plug into the negative COM jack Insert the red test lead banana plug into the V Hz Cap C jack If value is not zero in the display Press the REL button to zero Touch the test prob...

Page 14: ...ll typically indicate 0 400 to 0 700V Reverse voltage will indicate OL Shorted devices will indicate near 0V and an open device will indicate OL in both polarities 6 13 Audible Continuity Test Set the...

Page 15: ...th new batteries Fuses rarely need replacement and blow almost always as a result of the operator s error Open the case and replace the blown fuse with ratings speci ed Warning Before attempting to op...

Page 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: