Major tech MT1875 Instruction Manual Download Page 10

6.3. Measuring Light

Set the function switch to the “Lux” scale and set the range to 
desired (“Lux” or “x10 Lux”) range.

Move the meter to face the photo detector to a light source in a 
horizontal position.

Read the illuminance nominal from the LCD display.

Over-range: If the instrument only display one “1” in the M.S.D. the 
input signal is too strong, and a higher range should be selected.

When the measurement is completed. Remove the photo detector 
from the light source.

Spectral sensitivity characteristic: To the detector, the applied photo 
diode with filters makes the spectral sensitivity characteristic almost 
meet C.I.E. (International Commission on Illumination) photopia 
curve V (

λ) as the following chart described.

100% (Relative Sensitivity)      Spectral Sensitivity

Wave length (nm)

80%

60%

40%

20%

0

V(

λ

)

400         500           600           700

10

Recommended Illumination:
Locations 

 

 

Lux

Office

 

Conference, Reception room 

 

200 to 750

 

Clerical work   

 

 

700 to 1,500

 

Typing drafting  

 

 

1000 to 2,000

Factory

 

Packing work, Entrance passage 

 

150 to 300

 

Visual work at production line 

 

300 to 750

 

Inspection work 

 

 

750 to 1,500

 

Electronic parts assembly line 

 

1500 to 3,000

Hotel

 

Public room, Cloakroom   

 

100 to 200

 

Reception, Cashier 

 

 

200 to 1,000

Summary of Contents for MT1875

Page 1: ...MT1875 6 in 1 Environmental Multimeter INSTRUCTION MANUAL...

Page 2: ...perating Instructions 9 6 1 Measuring Sound Level 9 6 2 Measuring Humidity 9 6 3 Measuring Light 10 6 4 Measuring Temperature 11 6 5 Measuring DC Voltage 11 6 6 Measuring AC Voltage 12 6 7 Measuring D...

Page 3: ...uctor sensor and Type K thermocouple The digital multimeter performs AC DC Voltage AC DC Current Resistance measurement and Audible Continuity Diode Temperature test 2 Safety Instructions This meter h...

Page 4: ...ctric condenser microphone inside 9 Photo Detector Long life silicon photo diode inside 10 Hz button The button at AC DC Voltage measurement and AC DC Current measurement and Hz measurement Function i...

Page 5: ...ructions Press the REL button to store the reading in the display and the REL indicator will appear on the display The display will now indicate the difference between the stored value and the measure...

Page 6: ...ns 170 x 78 x 48mm Weight 335g including holster Accuracy is given at 18 C to 28 C 65 F to 83 F less than 70 RH 5 2 Sound Level Measurement range 35 to 100dB Resolution 0 1dB Frequency Range 30Hz to 1...

Page 7: ...erload Protection 250V DC or AC RMS for 400mV ranges and 250V DC or 250V AC RMS for other ranges 400 0mV 4 000V 40 00V 400 0V 600V 1 4 digits 1 5 4 digits DC Voltage Auto Ranging Range Accuracy Functi...

Page 8: ...load Protection 500mA 660V and 10A 600V Fuse AC Response 50Hz to 400Hz Maximum Input 400mA DC or 400mA AC RMS on uA mA ranges 10A DC or AC RMS on 10A range 1 2 2 digits 1 5 2 digits 400 0 4 000k 40 00...

Page 9: ...ound Level Set the function switch to the dB position Move the meter to face the microphone to a sound source in a horizontal position The C weighting curve is nearly uniform over the frequency range...

Page 10: ...teristic To the detector the applied photo diode with lters makes the spectral sensitivity characteristic almost meet C I E International Commission on Illumination photopia curve V as the following c...

Page 11: ...ed plug to the V Hz CAP C jack Touch the end of the temperature sensor to the area or surface of the object to be measured The display will show the temperature reading value C or F respectively 6 5 M...

Page 12: ...into the uA mA jack For current measurements up to 10A DC set the function switch to the yellow 10A position and insert the red test lead banana plug into the 10A jack Press the MODE button to indicat...

Page 13: ...lack test lead banana plug into the negative COM jack Insert the red test lead banana plug into the V Hz Cap C jack If value is not zero in the display Press the REL button to zero Touch the test prob...

Page 14: ...ll typically indicate 0 400 to 0 700V Reverse voltage will indicate OL Shorted devices will indicate near 0V and an open device will indicate OL in both polarities 6 13 Audible Continuity Test Set the...

Page 15: ...th new batteries Fuses rarely need replacement and blow almost always as a result of the operator s error Open the case and replace the blown fuse with ratings speci ed Warning Before attempting to op...

Page 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: