background image

 

 

 

 

 

MS361 

Microwave Motion Sensor   

 

 

 

 

 

 

 

 

 

Instruction Manual 

 

 

Thank you for purchasing the Major Tech MS361 Microwave Motion Sensor   

 

The  MS361  uses  Microwave  technology  (5.8GHz)  for  the  sensor 

thus detecting even the slightest movement in its detection zone to 

turn  lighting  on  and  off  based  on  occupancy.  The  MS361  can  be 

installed  into  existing  light  fittings  or  in  new  lights.  If  installed  and 

mounted on the ceiling at a height of around 2.5m, the detection range (radius) can be adjusted 

to a minimum of 3m and a maximum of 12m. The light can be set to stay on for any period of 

time  from  approximately 10 seconds  to  a  maximum of 12 minutes.  Detection  is possible  to  go 

through  doors,  panes  of  glass  or  thin  walls.    Major  Tech  Microwave  Sensor  is  ideal  for  home 

use and also in educational and commercial properties. 

 

 

SPECIFICATION: 

Power Sourcing: 220 -240V/AC                        Detection Range: 360°/180

°

 

Power Frequency: 50Hz                                    Detection Distance: wall::5-15m(adjustable) 

Ambient Light: <3-2000LUX (adjustable)                                          Celling:2-8m(radius),adjustable 

HF System: 5.8GHz CW radar, ISM band      Transmission Power: <0.2mW 

Time Delay: Min. 10sec ± 3sec                          Installation Height: wall:1.5-3.5m       

                      Max.12min ± 1min                                                          celling:2-10m 

Rated Load: 500W                                              Power Consumption: approx 0.9W 

                      200W                                                Detection Motion Speed: 0.6-1.5m/s 

 

FUNCTION:

 

 

 

Can identify day and night:

 The sensor works in the day and at night when it is adjusted 

to 

the “sun” position (max). The sensor works in ambient light in less than 3LUX when it is 

adjusted  to 

the  “moon”  position  (min).  As  for  the  adjustment  pattern,  please  refer  to  the 

testing pattern. 

 

SENS  adjustable:

  The  sensor  can  be  adjusted  according  to  the  location.  The  detection 

distance of low sensitivity can be only 2m and for high sensitivity 16m which will be suitable 

for a large room. 

 

Time-Delay  is  added  continually:

  When  it  receives  the  second  induction  signals  within 

the first induction, it will restart timing. 

 

Time

–Delay is adjustable.

  It can  be  set  ac

cording to the consumer’s requirements. The 

minimum time is 10sec ± 3sec. The maximum is 12min ±1min. 

 

NOTE:  The  high-frequency  output  of  the  HF 

sensor  is  <0.2Mw-  that  is  just  one  5000

th

  of  the 

transmission

 

power  of  a  mobile  phone  or  the 

output of a microwave oven. Children safe. 

 

INSTALLATION:

 (see diagram)

 

 

Switch off the power. 

 

Fix  the  bottom  on  the  selected  position  with  the  inflated 

screw through the screw holes at the side of the sensor. 

 

Connect the power and the load to the sensor as per the 

connection-wire sketch diagram. 

 

Switch on the power and test. 

Reviews: