Installation and 

Operating Instructions

Approved to ANSI Z21.60 / CSA 2.26

WARNINGS

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property damage, personal injury or loss of 

life.

–  Do  not  store  or  use  gasoline  or  other 

flammable vapors and liquids in the vicinity 

of this or any other appliance.

–  WHAT TO DO IF YOU SMELL GAS
  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately  call  your  gas  supplier  from 

a  neighbor's  phone.  Follow  the  gas 

supplier's instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

–  Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

This gas log set is to be installed only in a 

solid-fuel burning  fireplace with a working flue 

constructed of noncombustible material.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-

ence.

VDY24/18D4

VDY30D3R

VDY24/18D5

VDY24/18D2A

321999
VDY log cover

Vented Gas Log Set

Models: 

VDY24/18, VDY30

Majestic • VDY 24/18, VDY 30 Gas Log Heater Installation/Owner's Manual • 32D1999 • Rev A • 08/16

"Duzy" Series

Summary of Contents for VDY24/18

Page 1: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qua...

Page 2: ...VDY24 18D4 14 VDY30D4 16 VDY24 18D5 18 VDY30D5 20 Glowing Ember Placement 22 Decorative Volcanic Rock Placement 22 CONTENTS Fireplace Draft Test 22 Flame Appearance 23 Operating Instructions 24 For Yo...

Page 3: ...ults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition 11 Young children should be carefully supervised when they are in the same roo...

Page 4: ...ounting to the floor FEATURES SPECIFICATIONS GAS PRESSURES Natural Propane LP Inlet Minimum 6 0 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Regulator Pressure 4 0 w c 10 0 w c NOTE An external regula...

Page 5: ...provided with the unit The damper stop must be installed as shown in Figure 2 to prevent full clo sure of the fireplace damper blade and provide a minimum flue opening per table below Should the clam...

Page 6: ...raised the minimum height dimension listed in the homeowner s manual must not be exceeded NOTE If the log set is equipped with a remote receiver a restrictive barrier may reduce the battery life by in...

Page 7: ...es CAUTION Use new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted b...

Page 8: ...iance burning MANUAL CONTROL Figure 6 The pressure regulator is preset and locked to discourage tampering If the pressure is not as specified replace with the correct part from the parts list in this...

Page 9: ...table for millivolt operation CHECKING SYSTEM OPERATION The millivolt system and individual components may be checked with a millivolt meter having a 1 1000 mV range Conduct each check shown in chart...

Page 10: ...972 Figure 9 LG971 VDY24_18D2A rear log Rear Log 1 LG971 Figure 10 2 Install the right log 2 on top of the control cover Slide the log back until touching the rear log 1 Visually check to verify the l...

Page 11: ...op of the control cover Slide the log back until touching the rear log 1 Visually check to verify the log is resting on the grate and control cover Figure 16 3 Install the left log 3 with its bottom g...

Page 12: ...in bottom of log with grate bar Figure 21 3 Place front right log 3 on right front of grate bar aligning cutout in bottom of log with grate bar Make sure log 3 touches log 1 Figure 21 4 Place back en...

Page 13: ...ning cutout in bottom of log with grate bar Figure 26 3 Place front right log 3 on right front of grate bar aligning cutout in bottom of log with grate bar Make sure log 3 touches log 1 Figure 26 4 Pl...

Page 14: ...aligning two 2 pins on grate with holes in bottom of log Figure 30 LG990 VDY2418D4 bottom front log Bottom Front Log 2 LG990 Figure 29 LG972 VDY24_18D2 base Locator Pins Control Cover LG972 Figure 30...

Page 15: ...er s Manual 32D1999 Rev A 08 16 LOG PLACEMENT LG993 VDY2418D4 left cross log Left Crossover Log 5 LG993 Figure 32 5 Place left top crossover log 5 against left top log Figure 32 LG994 VDY2418D4 right...

Page 16: ...ase aligning two 2 pins on base with holes in bottom of log Figure 35 LG995 VDY30D4 bottom log Bottom Front Log 2 LG995 Figure 34 LG976 LG976 VDY30D2A base Locator Pins Control Cover Figure 35 LG996 V...

Page 17: ...30D4 lt cross top rt logs Right Top Log 6 Left Crossover Top Log 5 LG998 Figure 37 LG999 VDY30D4 small front log 5 Place left top crossover log 5 up against left top log Figure 37 6 Rest right top log...

Page 18: ...ligning two 2 pins on base with holes in bottom of log Figures 39 and 40 LOG PLACEMENT LG972 VDY24_18D2 base Locator Pins Control Cover LG972 Figure 39 LG1000 VDY2418D5 BACK LOG Back Log 1 LG1000 Figu...

Page 19: ...est other end of middle left log 4 behind middle right log Figure 42 5 Place middle right log 5 on top of bottom right log Figure 42 6 Rest top right log 6 on back log and bottom right log Figure 43 7...

Page 20: ...PLACEMENT LG976 LG976 VDY30D2A base Locator Pins Control Cover Figure 45 LG1005 VDY30D5 back log Back Log 1 LG1005 Figure 46 LG1006 VDY30D5 bottom logs Bottom Left Log 3 Bottom Right Log 2 LG1006 Figu...

Page 21: ...re 49 5 Place middle right log 5 on top of bottom right log Figure 49 LG1009 VDY30D5 top logs Top Left Log 7 Top Right Log 6 LG1009 Figure 50 6 Place top right log 6 on middle right log and back log F...

Page 22: ...nce on the logs It is important to periodically clean and inspect the logs per the cleaning and servicing section of the manual FIREPLACE DRAFT TEST FIREPLACE DRAFT TEST METHOD To determine if your fi...

Page 23: ...H PILOT ONLY PILOT FLAME APPEARANCE The pilot flame must always be present when appliance is in operation It should touch the thermocouple or ther mopile body INITIAL STARTUP During manufacturing fabr...

Page 24: ...settle on the floor WHAT TO DO IF YOU SMELL GAS Do not attempt to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a n...

Page 25: ...iously Instead of pushing and releasing the piezo button light a match and hold the flame to the end of the pilot and ignite the pilot MILLIVOLT CONTROL LIGHTING INSTRUCTIONS TO TURN OFF GAS TO HEATER...

Page 26: ...rance to the side wall FP2857 millivolt wiring THTP TP TH Optional Wall Switch or Remote Receiver Switch Millivolt Valve Pilot Figure 54 Attach Remote Receiver Wires to Terminals FP2857 NOTE Failure t...

Page 27: ...nt or particles with vacuum or brush Failure to keep air intake holes clean will result in sooting and poor combustion If embers rock wool have turned a rust color and become brittle remove old embers...

Page 28: ...3 Fireplace spilling 1 Low line pressure 2 Pilot is partially clogged 3 Defective thermopile 1 Gas leak 2 Control valve defective 1 Gas supply turned off or manual shutoff valve closed 2 Control knob...

Page 29: ...er orifice is clogged 1 Burner orifice is clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion wh...

Page 30: ...24D0305 24D0306 30 MODELS Ref Description VDY30NMP VDY30PMP VDY30NVP VDY30PVP 1 Main Injector 32D0090 32D0113 32D0090 32D0117 2 Control Knob 27D0602 27D0602 18D0603 18D0603 3 Manual Control Valve w Pi...

Page 31: ...II LOG SERIES Ref Description Qty VDY24 18D2 VDY30D2 1 Rear Log 1 32D0400 32D0410 2 Right Log 1 32D0401 32D0411 3 Left Log 1 32D0402 32D0412 4 Top Log 1 32D0403 32D0413 DUZY III LOG SERIES Ref Descri...

Page 32: ...PLACEMENT PARTS 1 2 3 4 5 6 7 LG1014 VDYD4 logs DUZY IV LOG SERIES Ref Description Qty VDY24 18D4 VDY30D4 1 Back Log 1 32D3101 32D3111 2 Bottom Front Log 1 32D3102 32D3112 3 Top Left Log 1 32D3103 32D...

Page 33: ...9 Rev A 08 16 1 2 3 4 5 6 7 8 LG1015 VDY2418D5 logs REPLACEMENT PARTS DUZY V LOG SERIES Ref Description Qty VDY24 18D5 1 Back Log 1 32D3121 2 Bottom Right Log 1 32D3122 3 Bottom Left Log 1 32D3123 4 M...

Page 34: ...1999 Rev A 08 16 REPLACEMENT PARTS 1 2 3 4 5 6 7 8 LG1016 VDY30D5 logs DUZY V LOG SERIES Ref Description Qty VDY30D5 1 Back Log 1 32D3131 2 Bottom Right Log 1 32D3132 3 Bottom Left Log 1 32D3133 4 Mid...

Page 35: ...e owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm sha...

Page 36: ...nce is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterati...