Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. H • 12/16
A. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as speci
fi
ed. Framing or
fi
nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Clearance to combustible material under the insert is 1/4
inch (6 mm). Clearance from top of
fi
replace opening for
combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)
above combustible material or outer wrap of factory built
fi
rebox.
Combustible facings must not extend behind the insert
surround. For non-combustible material speci
fi
cations
refer to section 1.E.
Figure 10.1 Mantel Clearance
10
10
Finishing
12 IN. MIN.
12 IN. MAX.
EXISTING NON-COMBUSTIBLE FACING
10 IN. MIN.
2 IN.
MAX.