Majestic JADE32IN-B Installation Manual Download Page 1

1

Majestic  •  JADE32IN-B, JADE42IN-B, JADE42IL-B Installation Manual  •  2619-986 Rev. B  •  10/19

Installation Manual

Installation and Appliance Setup

CAUTION!  Risk of Fire!  DO NOT

 store instruction manuals inside fireplace cavity.                            

High temperatures could cause a fire.                                     

INSTALLER:  Leave this manual with the appliance, not inside the appliance. 

CONSUMER:  Retain this manual for future reference.  Do not store inside the appliance.

NOTICE: DO NOT

 discard this manual!

• 

DO NOT

 store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately  call  your  gas  supplier  from 

a neighbor’s phone. Follow the gas sup

-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death, or 

property damage. 

Models:

JADE32IN-B
JADE42IN-B
JADE42IL-B

This appliance may be installed as an OEM 

installation  in  manufactured  home  (USA 

only) or mobile home and must be installed 

in  accordance  with  the  manufacturer’s 

instructions  and  the 

Manufactured Home 

Construction  and  Safety  Standard,

 

Title 24 

CFR, Part 3280 

in the United States, or the 

Standard  for  Installation  in  Mobile  Homes, 

CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 

of  gas  indicated  on  the  rating  plate.  This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A  barrier  designed  to  reduce  the  risk  of 

burns from the hot viewing glass is provided 

with this appliance and shall be installed for 

the  protection  of  children  and  other  at-risk 

individuals.

Decorative barrier front must be ordered separately at 

time of appliance purchase.  See Section 3.A.

Summary of Contents for JADE32IN-B

Page 1: ...ed installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Models JADE32IN B JAD...

Page 2: ...oved Pipe 21 E Use of Elbows 22 F Use of Flex Vent SLP FLEX Series 6 5 8 Inch 24 G Vent Diagrams 25 5 Vent Clearances and Vent Framing A Vent Clearances to Combustibles 37 B Wall Penetration Framing F...

Page 3: ...ed ___________________________ Gas Section 9 Pg 54 57 Proper appliance for fuel type ___________________________ Was a conversion performed ___________________________ Leak check performed and inlet p...

Page 4: ...cial and or local authorities having jurisdiction for installations at elevations above 4500 feet 1370 m Check with your local gas utility to determine proper orifice size B Glass Specifications Heart...

Page 5: ...or plastered or unplastered shall be considered combustible materials G Electrical Codes NOTICE This appliance must be electrically wired and grounded in accordance with local codes or in the absence...

Page 6: ...vented gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or...

Page 7: ...ury or property damage For assistance or additional information consult a qualified service technician service agency or your dealer Figure 2 1 Good Faith Wall Surface Temperatures Above Appliance B G...

Page 8: ...Electric Shock DO NOT use this appliance if any part has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and or gas control...

Page 9: ...Appliance Dimensions JADE32IN B Location Inches Millimeters M 16 3 4 425 N 6 5 8 168 O 34 3 8 873 P 2 3 16 56 Q 6 152 R 17 1 4 438 S 25 7 8 657 T 38 1 2 978 U 6 1 8 156 V 7 1 2 191 W 10 3 8 264 X 7 3...

Page 10: ...1 W 10 3 8 264 X 7 3 4 197 Location Inches Millimeters A 48 1219 B 43 1092 C 39 1 16 993 D 15 1 4 387 E 33 11 16 856 F 3 1 2 89 G 7 178 H 46 1 2 1181 I 9 13 16 249 J 9 13 16 249 K 1 2 13 L 37 3 4 959...

Page 11: ...0 D G E C B A F Barrier Mesh Integral to Decorative Barrier Front H Dimensions are actual decorative barrier front dimensions Use for reference only Figure 3 3 Decorative Barrier Front Dimensions CFTF...

Page 12: ...ecorative barrier front must be ordered at time of fireplace purchase If decorative barrier front is not present contact dealer Note See Section 10 for hearth mantel and finishing requirements PFF DEC...

Page 13: ...N PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference Figure 3 5 Appliance Locations A E A C TOP VENT ONE 900 ELBOW ALCOVE INST...

Page 14: ...p and side Drywall or combustible materials mini mum 1 2 inch thick are designed to contact the non combustible material appliance as called out in Section 10 Finishing This appliance has been thoroug...

Page 15: ...1 8 millimeters 89 51 1219 791 JADE42IN B JADE42IL B Inches 3 1 2 2 48 48 1 2 millimeters 89 51 1219 1232 Measurement for Trim Kit 3 1 2 in Additional Finishing Material Thickness Measurement without...

Page 16: ...ce Bottom of Appliance to Ceiling Minimum Clearance to Combustible Materials JADE32IN B JADE42IN B JADE42IL B Inches 12 1 4 8 3 4 39 82 18 millimeters 311 222 991 2083 457 Framing Dimensions Passive H...

Page 17: ...ers 51 1219 1232 Mesh screen required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches or greater Mesh screen recommended for front discharge or...

Page 18: ...Gas line holes and other openings should be sealed with caulk with a minimum of 300 F continu ous exposure rating or stuffed with unfaced insulation If the appliance is being installed on a cement su...

Page 19: ...r other materials Failure to keep insulation or other materials away from vent pipe could cause overheating and fire WARNING Figure 4 2 Staggered Termination Caps H minimum may vary depending on regio...

Page 20: ...et to building or the combustion air inlet to any other appliance termination mechanical or non mechanical 9 in 229 mm 12 in 305 mm I clearance to a mechanical powered air supply inlet All mechanical...

Page 21: ...X 6 5 8 inch and SLP FLEX7 7 inch venting systems DO NOT mix pipe fittings or joining methods from different manufacturers SLP FLEX and SLP FLEX7 venting cannot be interchanged SLP FLEX 6 5 8 Inch Ven...

Page 22: ...pe is allowed between two 45 elbows See Figure 4 5 Figure 4 6 shows the vertical and horizontal offsets for SLP elbows Figure 4 5 HORIZONTAL VERTICAL RUN RISE E F F E C T I V E L E N G T H Y X X X Ven...

Page 23: ...re shown using the effective length of pipe See Section 12 A Figure 12 1 for information on effective length of pipe components Horizontal terminations are measured to the outside mounting surface fla...

Page 24: ...A support is required at each change in venting direc tion and in any location where it is necessary to maintain the necessary clearance to combustibles A simple up and out installation Figure 4 10 re...

Page 25: ...be installed horizontally See Figure 4 15 Elbows may be placed back to back anywhere in the system Any 90 elbow may be replaced with two back to back 45 elbows When penetrating a combustible wall a wa...

Page 26: ...tion See Figure 4 10 H1 V1 V Minimum H1 Maximum JADE42IN B JADE42IL B JADE32IN B 90 Elbow Not Allowed 1 ft 305 mm 1 ft 305 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 3 ft 914 mm 4 ft 1 2 m 3 ft 914 mm 5 f...

Page 27: ...mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 3 ft 914 mm 4 ft 1 2 m 6 ft 1 8 m 4 ft 1 2 m 6 ft 1 8 m 15 ft 4 6 m 5 ft 1 5 15 ft 4 6 m H1 H2 MAX 15 ft 4 6 m V1 H1 H2 MAX 40 ft 12 2 m...

Page 28: ...eed 40 ft 12 2 m CAUTION The SLP HRC SS termination caps are not approved for use with these models May lead to elevated glass temperature that may cause tempered glass breakage JADE42IN B JADE42IL B...

Page 29: ...1 m Risk of Fire This vent configuration can ONLY be used for JADE42IN B Natural Gas appliance WARNING CAUTION The SLP HRC SS termination caps are not approved for use with these models May lead to el...

Page 30: ...al 2619 986 Rev B 10 19 30 Top Vent Vertical Termination No Elbow Figure 4 16 V1 60 ft Max 18 3 m Note Use SLP Series components only Note If installing a vertical vent termination off the top of the...

Page 31: ...haust Restrictor Installation 1 JADE42IN B JAD42IL B Only Remove inner heat shield by removing two wing nuts from top front of heat shield and two screws that secure the heat shield to back wall of fi...

Page 32: ...t 4 6 m V1 V2 H MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H cannot exceed 40 ft 12 2 m JADE42IN B JADE42IL B V1 Minimum H Maximum V2 V1 V2 Minimum 1 ft 305 mm 2 ft 610 mm 2...

Page 33: ...X 14 ft 4 3 m V1 V2 H1 H2 MAX 40 ft 12 2 m No specific restrictions on this value EXCEPT V1 V2 H1 H2 cannot exceed 40 ft 12 2 m JADE42IN B JADE42IL B V1 Minimum H1 H2 Maximum V2 V1 V2 Minimum 1 ft 305...

Page 34: ...MAX V2 MIN H2 MAX V3 MIN 2 1 2 ft 762 mm 4 ft 1 2 m 4 ft 1 2 m 4 ft 1 2 m 3 1 2 ft 1 0 m V1 V2 V3 H1 H2 Maximum 40 ft 12 2 m V1 H1 V2 V3 H2 Figure 4 20 Four 90 Elbows Top Vent Vertical Termination co...

Page 35: ...a minimum of a NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney...

Page 36: ...apping screws Attach one section of flexible vent pipe to the inlet collar on top of the DV 46DVA GCL adapter with three self tapping screws To minimize cold air drafts seal around the flex vents at t...

Page 37: ...arance bottom sides Heat Shield Wall Shield Firestop Heat Shield WALL 3 in 76 mm top clearance 1 in 25 mm clearance around vertical sections B Wall Penetration Framing Firestops Combustible Wall Penet...

Page 38: ...g Firestop Floor Penetra tion Framing WARNING Risk of Fire DO NOT pack insu lation around the vent Maintain clearances to vent to prevent overheating A ceiling firestop MUST be used between floors and...

Page 39: ...screws and discard See Figure 6 1 2 Fold up top heat shield to 90 degrees as shown in Figure 6 2 REMOVE SCREWS Figure 6 1 JADE42IN B JADE42IL B Shipping Position Figure 6 2 JADE42IN B JADE42IL B Top H...

Page 40: ...eps Heat Management System options are HEAT ZONE GAS The heat is diverted into an adjacent room HEAT OUT GAS The heat is diverted outside the home building Smart Wall TV Kit The warm air from the appl...

Page 41: ...r nailing tab Optional Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance Risk of Fire Prevent contact with Sagging or loose insulation In...

Page 42: ...ustible components from the shipping position and set aside 2 Remove the lower cover panel by removing two screws located on the lower left and right sides of the appliance opening Retain screws Lift...

Page 43: ...below including the slip section that connects directly to the horizontal termination cap Apply a bead of silicone sealant 300 F minimum con tinuous exposure rating inside the female outer pipe joint...

Page 44: ...p section See Figure 7 4 120 Figure 7 5 Securing Vertical Pipe Sections C Secure the Vent Sections WARNING Risk of Fire Explosion or Asphyxiation Improper support could allow vent to sag and separate...

Page 45: ...B 10 19 D Disassemble Vent Sections Rotate either section see Figure 7 7 so the seams on both pipe sections are aligned as shown in Figure 7 8 Pull carefully to separate the pieces of pipe Figure 7 8...

Page 46: ...ove the roof SEAL Figure 7 9 Assemble and Install Storm Collar CAUTION Risk of Cuts Abrasions or Flying Debris Wear protective gloves and safety glasses during instal lation Sheet metal edges are shar...

Page 47: ...xisting heat shields using the screws supplied with the extended heat shield Refer to vent components diagrams in the back of this manual Rest the small leg on the extended heat shield on top of the p...

Page 48: ...rcuits to mitigate the interference potential If interference is occurring on the same circuit the use of surge protectors may help alleviate the interference 8 Electrical Information Valve Control Ac...

Page 49: ...erates on a 6 volt 1 5AMP system Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries not included into the battery pack before u...

Page 50: ...NGE INTERMITTENT PILOT IGNITER NG 2106 169 HOT NEUTRAL JUNCTION BOX 110 120 VAC I S IFT CONTROL MODULE 2326 130 VALVE NG 2166 302 BLK BLACK RED GREEN ORANGE BRN RED RED WHITE WIRE ASSEMBLY 2118 170 WI...

Page 51: ...ROL BRN BLK OPTIONS FAN GFK 160A IFT RC150 WIRELESS WALL SWITCH IFT RC400 REMOTE CONTROL IFT AUX AC MODULE CABLE 2326 152 RF MODULE 2326 120 RF MODULE 2326 120 2326 150 LED s GREEN MAIN WIRE HARNESS N...

Page 52: ...PILOT IGNITOR 2106 169 HOT NEUTRAL JUNCTION BOX 110 120 VAC I S IFT CONTROL MODULE 2326 130 VALVE NG 2166 302 BLK GREEN ORANGE BRN WIRE HARNESS 2326 132 AC MODULE CABLE 2326 152 RF MODULE 2326 120 IF...

Page 53: ...he switch box connect the black hot wire and red switch leg wire to the wall switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction box as shown Ad...

Page 54: ...mmonwealth of Massachusetts ap proved 1 2 in 13 mm T handle manual shut off valve and flexible gas connector are connected to the 1 2 in 13 mm control valve inlet If substituting for these components...

Page 55: ...or compliance 2 Remove the two screws that secure the pilot shield to the burner bracket and remove the two screws that secure the pilot assembly to the burner bracket Remove the one screw that secure...

Page 56: ...Please consult provincial and or local authorities having jurisdiction for installations at elevations above 4500 feet 1370 m Check with your local gas utility to determine proper orifice size Figure...

Page 57: ...w 9 inches of horizontal vent pipe Adjust air shutter for different vent runs See Figure 9 5 Loosen the 1 4 inch screw Twist the air shutter to adjust Air shutter may be opened for longer horizontal v...

Page 58: ...those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of M...

Page 59: ...ace opening Ensure that the 1 8 inch gap is maintained between the factory installed non combustible board and the surrounding drywall See Figure 10 1 Secure the drywall to the framing with screws a m...

Page 60: ...irements Do not drill or install screws which may penetrate the lower cover panel as this will restrict required access to the glass battery backup and control module See Figure 10 2 Note If the desir...

Page 61: ...m clear ances as specified Framing closer than the minimums list ed must be constructed entirely of non combustible materi als i e steel studs concrete board etc Note Measurement is taken from top of...

Page 62: ...KED CEILING CEILING DO NOT INSTALL FINISHING MATERIAL ON THIS SURFACE 2 IN MIN OPENING MUST NOT BE BLOCKED CEILING 12 1 4 IN 8 3 4 IN SIDE DISCHARGE DISCHARGE SLOTS ON BOTH SIDES OF APPLIANCE FRONT DI...

Page 63: ...BUSTIBLE FINISHING MATERIAL 0 1 IN THICK CFTF DECORATIVE FRONT SHOWN DRYWALL OR EQUIVALENT 1 2 IN Both the CFTF and PFF decorative barrier fronts are de signed to overlap finish materials 0 inches to...

Page 64: ...front See Figure 10 10 If the desired look is to include the outer decorative barrier front trim finishing materials up to 1 3 16 around the fireplace opening See Fig 10 11 For this installation the...

Page 65: ...CFTF Front Without Outer Decorative Front Trim CFTF Decorative Front Non Combustible Finish Material 1 6 Inches Thick 0 IN 0 IN CFTF 0 IN Figure 10 14 Clearances to Appliance Opening Without Outer De...

Page 66: ...This diagram specific to these models JADE32IN B JADE42IN B JADE42IL B 82 IN MIN FIREPLACE OPENING 2 X 4 FRAMING 2 X 4 OR 2 X 6 FRAMING CHASE CEILING 1 2 INCH WALL SHEATHING FINISHING MATERIAL REQUIR...

Page 67: ...for use with the JADE42IN B JADE42IL B and JADE32IN B models Install the LED lights per the instructions included in the kit E Install Stones Optional An optional stones kit is available for use with...

Page 68: ...engaged by vi sually verifying that glass latches have engaged both left and right tabs on the glass frame 4 Verify the bottom two glass latches have engaged the glass frame tabs by grasping the bott...

Page 69: ...Barrier Front WARNING Risk of Fire Install ONLY decorative barrier fronts approved by Hearth Home Technologies Unap proved decorative barrier fronts could cause fireplace to overheat IMPORTANT This f...

Page 70: ...SLP45 45 Elbow SLP90 90 Elbow Effective Height Length SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop SLP WS Wall Shield Firestop 10 7 8 in 276 mm 8 7 8 in 225 mm 1 1 2 in 38 mm 8 11...

Page 71: ...xisting heat shields must be field trimmed If wall thickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3...

Page 72: ...nation Kit 14 in 356 mm 14 1 16 in 357 mm 7 1 2 in 192 mm 10 3 4 in 273 mm SLP CCS BK Cathedral Ceiling Support Box Black SLP DCF BK Ceiling Firestop Black SLK SNKD Snorkel Termination Cap SLP TVHW Ve...

Page 73: ...6DVA GCL Coaxial Colinear Appliance Connector 768 380A Stainless Steel Flex Pipe COAXIAL to COLINEAR VENTING Figure 12 5 Coaxial to Colinear Vent Components SLP HHW2 Horizontal High Wind Termination C...

Page 74: ...ote Wire harnesses required to power the PVI SLP B connect to the appliance and are ordered separately from PVI SLP B Contact your dealer to order 16 IN 406 mm 15 IN 381 mm 16 11 16 IN 424 mm 9 3 16 I...

Page 75: ...to order Figure 12 7 PVLP SLP Vent Components PVLP HS Heat Shield 14 IN 356 mm 15 1 2 IN 394 mm 11 1 2 IN 292 mm 8 IN 203 mm 4 3 8 IN 112 mm 10 IN 254 mm 5 1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 m...

Page 76: ...E42IN B and JADE42IL B models Follow the instructions supplied with the kit for installation Contact your dealer if you have questions WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Tech...

Reviews: