5
75D2525
DVM Series Direct Vent Gas Fireplace
product features and
code approVal
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
product specIfIcatIons
FP2407
DVM/MDV features
Off/Pilot/On Knob
Optional Remote Receiver
Figure 1 -
500DVM and 600DVM Fireplace
(Millivolt Unit Shown — Also Available with
Signature Command System)
Hi/Lo Knob
Blower Control
On/Off/RS Switch
Ignitor
1/2"
Nailing
Flange
5/8"
Nailing
Flange
1/2"
Nailing
Flange
Eyebrow
Insulation
Board
Standoff
FP2407
w
arn
Ing
do not remove insulation board.
gas pressures
hIgh eleVatIons
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural
Propane (LP)
Inlet Minimum
4.0” w.c.
11.0” w.c.
Inlet Maximum
14.0” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
max.Input min. Input orifice
model
fuel
Btu/h
Btu/h
size
500DVMNV
Nat.
30,000
21,500
7/64"
500DVMPV
LP
30,000
23,500
#51
500DVMNSC Nat.
30,000
21,500
7/64"
500DVMPSC
LP
30,000
23.500
#51
600DVMNV
Nat.
32,000
22,000
#34
600DVMPV
LP
32,000
26,000
#50
600DVMNSC Nat.
32,000
22,000
#34
600DVMPSC
LP
32,000
26,000
#50
gas specIfIcatIons & orIfIce sIZe