Majestic fireplaces NVCR36R Series Installation And Homeowner’S Operating Manual Download Page 1

INSTALLER/CONSUMER 
SAFETY INFORMATION

PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE.
IMPORTANT:

 Read all instructions 

and warnings carefully before starting 
installation. Failure to follow these 
instructions may result in a possible 
fire hazard and will void the warranty.

WARNING: If the information in this 
manual is not followed exactly, a fire 
or explosion may result causing 
property damage, personal injury or 
loss of life.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service 
agency or the gas supplier. Do not 
store or use gasoline or other 
flammable vapors and liquids in the 
vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
1.  Open windows. 
2.  Do not touch any appliance.
3.  Extinguish any open flame.
4.  Do not use the phone in your 
  building.
5.  Immediately call your gas supplier 

from a neighbor’s phone.

6.  Follow your gas supplier’s 
  instructions.
7.  If you cannot reach your gas 
  supplier, call the fire department.

Decorative Gas Appliances

Models: NVCR36R, NVCR36L

Installation and Homeowner’s 

Operating Manual

1315

NVCR

Cover

4/30/99   djt

CERTIFIED

DESIGN

CERTIFIED

20001315  10/06  Rev. 5

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

f i r e - p a r t s . c o m

Summary of Contents for NVCR36R Series

Page 1: ...ency or the gas supplier Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch...

Page 2: ...ance 7 Insulating for Cold Climates 7 Installation Framing 8 Gas Line Installation 8 Option for E Models ONLY EB1 Receptacle Hook Up 8 Remote Wall Switch 9 Slide the Appliance in Place 9 Level and Sec...

Page 3: ...ance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung in the area of it 9 Under no circumstance should any solid fuels wood coal paper or cardboar...

Page 4: ...178mm 14 362mm Gas Line Access 41 1054mm Rough Opening Height 12mm 1019mm 36 914mm 21 540mm 497mm 6 172mm 251mm 1 25mm Rough Opening Depth 16mm Recessed Nailing Flange 21 556mm 559mm 10 254mm 12mm 12m...

Page 5: ...5 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c High Elevations Input ratings are shown in BTU per hour and are certi ed without deration for elevations up...

Page 6: ...l for cold climate not a requirement for unit operation Termination Cap Storm Collar Pan Flashing Draftstop Outside Air Kit Gas Line Access Electrical Access Screen Grate Hearth Panels Surround Nailin...

Page 7: ...ailing anges FP800 FP549CR Corner unit nailing flanges 5 3 99 djt Nail Top Standoffs Nail Side Nailing Flanges Fig 4 Adjustable drywall strip nailing anges FP549CR Insulating for Cold Climates When an...

Page 8: ...re test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only ap proved ttings Always provide a union so that gas line ca...

Page 9: ...g connected gently slide or lift the appliance to the desired location Level and Secure the Appliance If nailing anges are not already installed attach anges with the screws provided Make sure applian...

Page 10: ...ion See venting installation instructions provided by the B vent manufacturer FP567 NVBR NVBC VENTING RUNS 11 12 97 Venting Runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 1 2 3 4 5 6 7 Horiz...

Page 11: ...sem bly Optional Thermal Vent Damper TVD6 7 Attach the thermal vent damper to the combustion dome with two 2 screws Be sure the tab points down Fig 12 Start the appliance and operate it for approximat...

Page 12: ...Fig 13a Mantel clearances Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim CFM146 Ref Mantel Ref Mantel from Top Shelf Depth of Comb Chamber V 14 356 mm A 18 457 mm W 12 305 mm B 16 4...

Page 13: ...he appli ance will not require purging When lit for the rst time the appliance will emit a slight odor for an hour or two This is due to paint and lubri cants used in the manufacturing process After e...

Page 14: ...mell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do...

Page 15: ...ormer Taking care of the Electronic Ignition units is almost identical to taking care of the Standing Pilot models See Maintenance sections on page 16 The hot sur face ignitor is the only component wh...

Page 16: ...mmend replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean glass after rst two weeks of opera tion In...

Page 17: ...essing Piezo red button 1 8 gap to pilot hood needed All wiring connections Replace Piezo ignitor Thermodisk For air in the lines Thermopile needs a minimum of 325mV Ad just pilot ame height All wirin...

Page 18: ...nnections between module and pilot operator on gas control Check for 24VAC across PV MV PV terminals on module if voltage is okay Re place gas control if not replace module NOTE if S8600B goes into lo...

Page 19: ...peci cations prices and discontinue colors and products at any time without notice NVCR36L R Ref Description NVCR36L NVCR36R 1 Log Set Complete 20001416 200014160 1a Log Rear 3043146 3043146 1b Log Fr...

Page 20: ...tion NVCR36L NVCR36R 9 Screen Rod 7554181 7554181 10 Brick Back 20000792 20000792 11 Side Brick 20000793 20000793 12 Ceramic Panel Outside 20001348 20001348 13 Ceramic Panel Inside 20001347 20001349 1...

Page 21: ...ol Thermal Vent Damper Description Glass Door Set Bi fold door for front of unit with solid panel on the side Completes connection from air kit to out of doors Electrical box for E models Wireless rem...

Page 22: ...22 Majestic Fireplaces NVCR Series B Vent 20001315 fire parts com...

Page 23: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Reviews: