To let the device power off completely, it is suggested that the interval of the power-off
and power-on is larger than 20s.
After the switch is powered on and starts, the configuration terminal will display some basic
manufacturing information of the switch, such as:
MyPower (R) Operating System Software
MyPower S12800 system image file (yflash0: /yflash/sp9b-g-8.1.0(1)-dbg.pck), version 8.1.0(1), Compiled on Aug 28 2015,
03:57:29
Copyright (C) 2015 Maipu Communication Technology Co.,Ltd.All Rights Reserved.
System ID
: 00017a6fa8c5
Hardware Model
: SM12800-12(V1)
Hardware Version : 002(Hotswap Supported)
MPU CPLD Version : 002
Monitor Version
: 1.20
Software Version : 8.1.0(1)
Software Image File : yflash0: /yflash/sp9b-g-8.1.0(1)-dbg.pck
Compiled
: Aug 28 2015, 03:57:29
The above displayed information on the start interface is just for reference. Please refer to
the actual display.
4.1.4 Check after Power on
Power on the switch. After loading all cards, check as follows to ensure that the later
configuration work can be done normally:
After the switch is powered on, the ventilation system works and check
whether there is the sound of the fan rotation and whether there is air
discharged from the ventilation holes of the switch.
View whether the indicators on the switch are normal.
Different models of switch devices have different indicators. For details, refer to
A Entire Device and Common Module Specifications
4.2 Access Network
4.2.1 Access Network via Ethernet Twisted Pair
The 10/100/1000Base-T electrical interface of the device adopts the RJ-45 connector. The port
supports MDI/MDIX auto-sensing and adopts class-5 or above twisted-pair to connect the
network.