Install the router to the workbench.
Install the router to the cabinet.
3.2.1
Install Router to Workbench
Place the router on the clean workbench. During the installation, pay attention to the
following:
Ensure the stability and well-grounding of the workbench.
There is 10cm heat dissipation space around the router.
Do not place heavy things on the router.
3.2.2
Installing the Router to the Cabinet
This section will describe the method to install the MP1800X-50 router in a 19''
standard cabinet.
Installation Preparation
The height of the MP1800X-50 router is 1U, so ensure that the enough installation
space is reserved for the router.
Check the grounding conditions and stability of the cabinet. Ensure the cabinet is
free from any inside/surrounding item having an adverse impact on the switch
installation.
Note:
1U is 44.45mm. U refers to Rack Unit (RU).
Installing the Tray to the Cabinet
The tray supports the router weight. If a tray is already on the cabinet, skip this section.
Note:
Ensure that the distance between the tray and the bottom cabinet is 2U and three
holes on the square hole bar is 1U, as sown in Figure 3-4.