![Maidaid Halcyon Evolution 535WS User'S Installation Manual Download Page 17](http://html1.mh-extra.com/html/maidaid-halcyon/evolution-535ws/evolution-535ws_users-installation-manual_3720428017.webp)
INSTRUCTION MANUAL FOR DISHWASHERS
Page 14 of 16
UK
Chap 7
SETTINGS
The following settings should only be configured by a qualified technician.
The parameters listed below can be set during installation of afterwards, accessing the settings menu as
follows:
Machine in standby with door open.
Press buttons
1
and
2
together (
ON/OFF
and
SPECIAL PROGRAMME SELECTION
) for 5 seconds
and enter the key
KEY 12
(buttons
3
and
4
to change the parameter,
1
to confirm).
Then press button
1
(
ON/OFF
) repeatedly to scroll through the following headings, enabling and/or
changing them using buttons
3
and
4
(the modified parameter is memorised without being confirmed).
The list of parameters may vary according to the type of dishwasher.
Language
Language selection
Boiler Set
Boiler temperature settings for programmes. In the versions with
atmospheric boiler (rinse pump) there are different settings for each
programme (b1
– b2 – b3)
Tank Set
Tub temperature regulation for programmes. Rinse pump versions have
different settings for each programme (t1
– t2 – t3)
ThermoStop
Enabling the Thermostop function, which guarantees the correct
rinse temperature.
Energy Saving
Enabling the Energy Saving function, which guarantees
energy savings when the dishwasher is on but not in use.
Manual Detergent
Manual operation of detergent doser
Manual Rinse Aid
Manual operation of rinse aid doser
Detergent Dose
Detergent dosing time
Rinse Aid Dose
Rinse aid dosing time
Water Hardness
Water supply hardness setting, for machines with built-in water softener, set
according to measured water hardness.
External Softenr Cycles
Cycle counter setting and activation to enable the Service alert for an
external water softener.
The Service alert can be cancelled by holding pressed all 4 buttons with the
machine off and the door open.
Manual Rinse Pump
Manual operation of the rinse pump
Manual Drain
Manual operation of the drain pump
Autostart Enable
Automatic enabling of automatic starting
Cycle Counter
Cycle counter
Once all necessary parameters have been set, to exit and save any changes simply press and hold
button
1
for a few seconds until the display switches off.