4. System components
│
UK
45
●
The ventilation unit has four Ø 125 mm
duct connections. For suitable plug
connectors with lip seal or pipe elbow
Maico catalogue or internet.
●
¾“ condensate discharge outlet, sleeve
with 28 mm diameter lip seal. For
connecting a drain hose. The condensate
discharge must run into a siphon as
otherwise
unwanted air
is sucked
into the ventilation unit through the drain
line, see also Chapter 6.4.
4.2 Room air controls
4.2.1 RLS 1 WR room air control
Standard room air control for
● WS 170 standard unit
● WS 170 comfort unit
For detailed information, see WS 170
operating and maintenance instructions.
4.2.2 Digital RLS D1 WR
room air control
Standard room air control for
● WS 170 bypass unit
For detailed information, see operating
instructions in separate packaging unit.
The RLS D1 WR can also be combined with
the standard or comfort unit.
4.2.3 Maximum number of controls and
sensors
RLS 1
WR
+
max. 4x
RLS 1
WR
+
1x CO
2
Sensor
or
1x VOC Sensor
or
several hygrostats.
RLS D1
WR
+
‒
+
1x CO
2
Sensor
or
1x VOC Sensor
or
several
hygrostats.
NOTICE
Damage to the unit.
Never operate an hygrostat
together with a CO
2
or VOC
sensor.
4.3 CO
2
sensor (SKD) / VOC sensor
(EAQ 10/2 air quality controller)
Also refer to connection option 4 in Chap. 6.11.
CO
2
sensor
for registering carbon dioxide.
The CO
2
content of the air is an indicator of
the quality of the room air. The higher the
CO
2
content, the worse the room air quality.
The ventilation unit only reacts to the CO
2
sensor if ventilation level 2 (nominal venti-
lation) is selected on the RLS 1 WR or
RLS D1 WR room air control.
VOC sensor (EAQ 10/2 Air quality control-
ler)
for controlling the fans according to the
air quality. The ventilation unit only reacts to
the VOC sensor if ventilation level 2 (nominal
ventilation) is selected at the (RLS 1 WR or
RLS D1 WR) room air control.
CO
2
and VOC sensor:
The ventilation unit
switches between the ventilation levels,
depending on the air quality.
●
If the air quality improves, the ventilation
unit switches over to ventilation level 1.
●
If the air quality worsens, the ventilation
unit switches over to ventilation level 3.
CO
2
and VOC switching points are perma-
nently stored in the control.
Switching points
control
Output voltage
sensor
< 2.5 V
Level 2 to
level 1
2.5 V at 900 ppm
< 5 V
Level 3 to
level 2
5 V at 1,000 ppm
> 5 V
Level 1 to
level 2
5 V at 1,000 ppm
> 7.5 V
Level 2 to
level 3
7.5 V at 1,100 ppm
To the control circuit board may be
connected only with
●
one CO
2
sensor or
●
one VOC sensor or
●
several hygrostats with potential-
free contacts.
Never operate a CO
2
sensor together
with a VOC sensor.
Summary of Contents for WS 170 L
Page 3: ......
Page 38: ...DE 12 Anhang Verdrahtungsplan WS 170 Komfortger t 36 12 2 Verdrahtungsplan WS 170 Komfortger t...
Page 40: ...DE 12 Anhang KNX Bus Konzept 38 12 3 KNX Bus Konzept...
Page 76: ...UK 12 Appendix KNX bus concept 74 12 3 KNX bus concept...
Page 116: ...FR 12 Annexe Concept bus KNX 114 12 3 Concept bus KNX...
Page 119: ......
Page 120: ......
Page 121: ......