Maico WS 170 KR Wiring Diagram Download Page 8

WIRING DIAGRAM

WS 170 KR

Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 8

WS 170 ventilation unit with differential pressure controller and RLS 1 WR or RLS
D1 WR room air control

W 5

k

P

W 1

G

N

Y

E

B

U

B

N

B

W 2

W 2 '

I I

I

I I I

B 1

L1

N

L1

N

N

L1

L1

N

L1

L1

N

O

T

LD

2

O

T

S

2

S

1

LD

3

LD

1

8

9
10

C O 2

B D E

O N / O F F

6

7

J u m p e r

1

N

A

b

lu

ft
Z

u

lu

ft

A 2

A

P E

N

L

A - WS 170 electronic slide-in module
A2 - Control circuit board: Jumper 8 bridged (= factory setting)
B - RLS D1 WR room air control
B1 - RLS 1 WR room air control
P - Differential pressure controller with potential-free relay contact k (provided by customer)
k - Switching output, potential-free relay contact
W5 - Connection cable for differential pressure controller (provided by customer)
If there is negative pressure in the room, the differential pressure controller switches the fans in the ventilation unit off.
This blocks the room air control RLS 1 WR. The LED display goes out. The unit is only released again when the differ-
ential pressure controller switches the fans back on. The ventilation unit runs again at the same ventilation level
as before it was blocked.

Summary of Contents for WS 170 KR

Page 1: ...1 N N e t z Z u l u f t N L 1 L 1 N L 1 L 1 N 1 2 3 4 5 6 7 8 9 1 0 CO2 BDE On Off Temp WH RD YE BU WH RD YE BU GNYE BU BN BN BU GNYE BN GNYE BU WH BU A2 0 10V BK T y p M1 J u m p e r a n z e i g e B...

Page 2: ...tilation level 3 Jumper settings J 1 3 Unit type 000 WS 170 J 4 5 Frost protection temperature J 6 No function J 7 Jumper 7 open Ventilation level 3 is reset after an hour J 8 RLS 1 WR or RLS D1 WR ro...

Page 3: ...2 BN GY YE GN PK WH B1 II I III LD3 LD2 LD1 S1 S2 B2 BN GY YE GN PK WH W2 BN WH PK GY GN YE A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B1 1 RLS 1 WR...

Page 4: ...ons without giving prior notice Page 4 WS 170 ventilation unit with RLS D1 WR room air control 8 9 10 CO2 BDE ON OFF 6 7 Jumper 1 A2 A W1 W2 W H B N B G N Y E B U B N PE N L A WS 170 electronic slide...

Page 5: ...B RLS D1 WR room air control B1 RLS 1 WR room air control H1 Display element e g glow lamp to be supplied by the customer W1 230 V AC connection cable W2 W2 Control cable for room air control W3 Cabl...

Page 6: ...umper 8 bridged factory setting Jumper 10 bridged sensor is detected B RLS D1 WR room air control B1 RLS 1 WR room air control CO2 SKD CO2 sensor VOC EAQ 10 2 air quality controller W1 230 V AC connec...

Page 7: ...pplied by the customer Connection to A2 control circuit board at CO2 terminals When connecting a hygrostat with potential free contact for demand driven removal of moisture the hygrostat must have a p...

Page 8: ...nic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control B1 RLS 1 WR room air control P Differential pressure controller with potential free relay con...

Page 9: ...ory setting B RLS D1 WR room air control B1 RLS 1 WR room air control GW1 Gateway frost protection heat register GW2 Gateway bypass shutter only WS 170 bypass unit T1 Supply air temperature sensor in...

Reviews: