Installations-, Inbetriebnahme- und Wartungsanleitung WS 160 Flat, WS 300 Flat
Installation, Commissioning and Maintenance Instructions for WS 160 Flat, WS 300 Flat
Notice d'installation, de mise en service et d'entretien WS 160 Flat, WS 300 Flat
EN
12
Maico Elektroapparate-Fabrik GmbH
I
Steinbeisstr. 20
I
78056 Villingen-Schwenningen
I
Germany I S49 7720 6940 I [email protected]
0185.1242.0001_RLF.9_12.22_DSW-AS
1 Safety
• Read
these instructions
and the
enclosed safety instruc-
tions
carefully and completely before installation.
• Follow the instructions.
• Pass these instructions on to the owner/operating com-
pany for safekeeping.
Safety devices are designed for your protection
and must not be bypassed or tampered with.
2 Scope of delivery
WS 160 Flat or WS 300 Flat
ventilation unit,
RLS 1 WR
con-
trol unit, set of installation aids (bracket, 4 screws, bush-
ing, retaining screw),
safety instructions
supplement,
quick start guide
and these
installation and commission-
ing instructions
.
3 Intended use
This ventilation unit with heat recovery is used for con-
trolled ventilation of apartments, offices or similar rooms.
The ventilation unit is only intended for domestic use and
similar purposes. No other or additional use is intended.
4 Unit overview
Unit types
WS 160 Flat unit types
WS 300 Flat unit types
WS 160 Flat ET
WS 300 Flat R
WS 160 Flat KET
WS 300 Flat L
WS 160 Flat BET
WS 300 Flat BR
WS 160 Flat KBET
WS 300 Flat BL
WS 160 Flat KBZET
WS 300 Flat KBR
WS 300 Flat KBL
R =
Right-hand version
L =
Left-hand version
B
= Bypass
K
= Preheating register
ET
= Enthalpy heat exchanger
Z =
Zone flap
4.1 Unit front
WS 160 Flat
F Front cover
USB USB connection
A1
Filter cover 1:
Shaft for G4 and/or F7 filter. Al-
ternative for F7 pollen filter = active carbon fil-
ter.
A2
Filter cover 2:
Shaft for G4 filter.
WS 300 Flat
F Front cover
USB USB connection
A1
Filter cover 1:
Shaft for G4 and/or F7 filter. Filter
configuration with G4 and F7 filters different for
right-hand and left-hand versions, see overview
figures below.
A2
Filter cover 2:
Shaft for G4 filter. Filter configura-
tion with G4 and F7 filters different for right-
hand and left-hand versions, see overview fig-
ures below.
4.2 Structure / duct connections
WS 160 Flat unit overview
Figure:
WS 160 Flat KBZET
I Outside air
II Supply air
III Exhaust air
IV Outgoing air
1 Control unit
RLS 1 WR
. Alternative control units:
RLS T1 WS
,
RLS T2 WS
or
RLS G1 WS
.
2 Supply air temperature sensor
4 Cable feedthrough for
power cable