13 Dismantling | UK
59
12.2 Technical data for PPB 30
External diameter
DN 160
Wall sleeve
(max. length)
PP 45 RHK: 500 mm
PP 45 RHL 800 mm
Wall thickness
320 - 790 mm
Air filter inside/outside
G3/G3
Air volume/unit
in exhaust air mode
45 m³/h
Degree of protection
IP X4
Sound pressure level,
at distance of 1 m
conditions without
obstructions
(ventilation level 1 to 5)
18 / 32 / 41 /
45 / 49 dB(A)
Rated voltage/
power frequency
230 V
50/60 Hz
Volumetric flow
heat recovery mode
ventilation level 1 to 5
5 / 12 / 18 / 22 / 26 m³/h
Volumetric flow
exhaust air mode
45 m³/h
Power consumption
(ventilation level 1 to 5)
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
Degree of heat
provision
73,3 % (level 3)
SPI
0.19 W / (m³/h)
SEC value
A (-39.41)
Permissible ducting
lengths with wired
connection
From star point
max. 25 m per
ventilation unit
Weight
slide-in module cpl.
3.6 kg
13 Dismantling
Ventilation units may only be dismantled by a
person with electrical training
.
!
DANGER
Danger of electric shock.
Before removing the front cover, disconnect
the ventilation unit at all poles from the power
supply, secure against being accidentally
switched back on and position a visible
warning sign.
14 Environmentally responsible
disposal
The ventilation unit and the packaging contain
parts that can be recycled, and should not
end up in the domestic waste.
Dispose of the
packaging material
in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.
Dispose of the air filter and the unit (at the
end of its useful service life) in an environ-
mentally-friendly way, in compliance with the
regulations valid in the country where you are.