10 Start-up | UK
45
LEDs
Parameter
Set value /
ventilation level
Setting /
description
Sensors
0
1
2
3
4
5
6
7
No sensor
1 internal sensor
1 internal 1 external sensor
1 internal 2 external sensors
1 internal 3 external sensors
0 internal s 1 external sensor
0 internal s 2 external sen
-
sors
0 internal s 3 external sen
-
sors
Select how many internal and external
sensors are connected/combined. The
PP 45 HYI internal sensor and the
PP 45 HY, PP45 CO2 and PP 45 VOC
external sensors are available.
ModBus
settings
1
2
3
RS-485 inactive
ModBus active 9600 baud
ModBus active 19200 baud
This adjuster activates ModBus and
sets the baud rate.
Notice: When the Modbus interface
is active, external sensors/LTs/RLS
cannot
be connected.
ModBus
address
1
2
3
4
5
6
7
Address 10
Address 11
Address 12
Address 13
Address 14
Address 15
Address 16
The ModBus address
is selected with this adjuster.
LED flashing modes: LED flashing rapidly LED flashing slowly