4 Operating keys, displays, LEDs
46
4 Operating keys, displays, LEDs
4.1 Operating keys, switches/buttons
Further information →
RLS 45 O
/
RLS 45 K
/
DS 45 RC
Operation with heat recovery (HR)
Display via operating mode LED.
RLS 45 O
/
RLS 45 K
: operating mode
LED
PP 45 RC
/
PPB 30 RC
: operating
mode LED orange
Units switch between ventilation and air
extraction at 60 second intervals.
RLS 45 O
/
RLS 45 K
/
DS 45 RC
Cross-ventilation without heat recov-
ery (e.g. summer operation).
Display via operating mode LED.
RLS 45 O
/
RLS 45 K
: operating mode
LED
PP 45 RC
/
PPB 30 RC
: operating mode
LED blue
Ventilation units run with fixed direction
of air flow in ventilation or air extraction
mode.
RLS 45 K
/
DS 45 RC
Ventilation level 1 to 5
.
Ventilation level 0 (ventilation Off) only
possible if Off function is activated
RLS 45 O
:
Ventilation level 1 to 5
.
Ventilation level 0 (ventilation Off) only
possible if Off function is activated.
RLS 45 K
/
DS 45 RC
Intermittent ventilation with ventila-
tion level 5
.
Intermittent ventilation can be selected
in heat recovery or cross-ventilation
mode. With
PPB 30 K
/
PPB 30 RC
units, system operation can only be un-
dertaken with basic settings. To switch
on,
press key for 2 seconds
, the
LED flashes slowly. On RC units, the
current operating mode LED flashes
2x, 5 times. Operating time of
30 minutes
. The ventilation unit then
switches back to the ventilation level
previously used. To cancel, press a key.
With the
PPB 30 RC
, the exhaust air
mode is triggered via the touch of a but-
ton (blue operating mode LED
2x 2 seconds).
In the service menu of the
PPB 30 RC
,
the
intensive ventilation
can also be
configured instead of the exhaust air
mode. Abort: Press a key.
RLS 45 K
/
DS 45 RC
Sleep mode with ventilation level 0
.
Sleep mode can be selected in heat re-
covery or cross-ventilation mode. With
PPB 30 K
/
PPB 30 RC
units, system
operation can only be undertaken with
basic settings. To switch on,
press key
for 2 seconds
, the
LED flashes
slowly.
On RC units, all 3 operating mode LEDs
light up and then go out one after an-
other. Operating time of
60 minutes
.
The ventilation unit then switches back
to the ventilation level previously used.
Abort: Press a key.
i
Intermittent ventilation, sleep mode or
system Off can be activated on
RLS 45
K
controller with optional switches.
When a function is switched on, the
LED flashes slowly.
Optional button/switch for the PPB 30
K exhaust air or intensive ventilation
mode.
If required, the
PPB 30
unit can be
switched to exhaust air mode (45 m³/h
without heat recovery) or intensive vent-
ilation mode (ventilation level 5 with heat
recovery) using an optional button/
switch. The commissioning software can
be used to set parameters for how long
these functions last and for the start
delay for the switch. Once the time has
elapsed, the ventilation unit switches
back to the previously used ventilation
level/operating mode.
i
For examples of dehumidification
strategies and splitting of the volumetric
flows when using several ventilation
units →
Summary of Contents for PP 45 O
Page 2: ...Inhaltsverzeichnis Deutsch 3 English 36 Fran ais 70...
Page 4: ...bersicht PP 45 4 bersicht PP 45...
Page 6: ...bersicht PPB 30 6 bersicht PPB 30...
Page 8: ...Steuerungskonzept PP 45 8 Steuerungskonzept PP 45...
Page 9: ...Steuerungskonzept PPB 30 9 Steuerungskonzept PPB 30...
Page 10: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 10 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Page 37: ...Table of contents 37 PP 45 RC 110 PPB 30 O 112...
Page 38: ...Overview of PP 45 38 Overview of PP 45...
Page 40: ...Overview of PPB 30 40 Overview of PPB 30...
Page 42: ...PP 45 control concept 42 PP 45 control concept...
Page 43: ...PPB 30 control concept 43 PPB 30 control concept...
Page 44: ...PP 45 RC PPB 30 RC wireless control concept 44 PP 45 RC PPB 30 RC wireless control concept...
Page 72: ...Vue d ensemble PP 45 72 Vue d ensemble PP 45...
Page 74: ...Vue d ensemble PPB 30 74 Vue d ensemble PPB 30...
Page 76: ...Concept de commande PP 45 76 Concept de commande PP 45...
Page 77: ...Concept de commande PPB 30 77 Concept de commande PPB 30...
Page 78: ...Concept de commande PP 45 RC PPB 30 RC radio 78 Concept de commande PP 45 RC PPB 30 RC radio...
Page 105: ...105 PP 45 PPB 30 Volumenstr me PP 45 PPB 30 volumetric flows D bits d air PP 45 PPB 30...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108 PP 45 O PP 45 K PP 45 O PP 45 K PP 45 O PP 45 K...
Page 110: ...110 PP 45 RC PP 45 RC PP 45 RC...
Page 111: ...111 PP 45 RC mit PP 45 HYI PP 45 RC with PP 45 HYI PP 45 RC avec PP 45 HYI...
Page 112: ...112 PPB 30 O PPB 30 O PPB 30 O...
Page 114: ......
Page 115: ......