12 Cleaning, maintenance

 Cleaning intervals are to be determined by the

operating company. Cleaning frequency depends
on ambient conditions and anticipated impair-
ments.

Before cleaning, switch off mains fuse, secure against be-
ing accidentally switched back on and position a warning
sign. If required, the unit is cleaned with a dry cloth.

EZR, DZR fans are maintenance-free.

 Despite this

, check

the unit from time to time

 for bearing noise, damage and

disproportionate vibration. If necessary, clean the fan as
described above.

 Never use water or a high-pressure cleaner to

clean the interior.

13 Fault rectification

 Fault finding and repairs only permissible when

carried out by qualified electricians.

 When the unit is at a standstill, check whether

the thermal overload protection of the motor has
reacted. Once the thermal overload protection has
cooled down, switch on the fan and check for un-
usual noise.

Malfunction

Cause, measures

Fan does 

not

 switch on.

No mains voltage.

 Check

whether the mains fuse has
failed. Switch on if neces-
sary.

Thermal overload protection
of the motor has triggered.

Motor too hot.

 Wait until

motor and temperature lim-
iter have cooled. Cool-down
time can be up to 

30

minutes. Only then switch
the fan on again.

Fan does 

not

 switch on.

Impeller not turning.

Check impeller. 

Ensure that

the impeller is not blocked
by foreign bodies. Switch off
the fan, secure it against be-
ing switched back on and
clean it. Check the fan for
unusual noises during oper-
ation.

Malfunction

Cause, measures

Deposits on the impeller
and in the housing caused
by dust in the air.

Operation without air filter.

Install air filter in duct sys-
tem. 

Never

 clean the in-

terior of the fan with water
or a high-pressure cleaner.

14 Spare parts

For spare parts → 

Unit overview [

}

 4]

. Only use original

spare parts.

When ordering, please provide the following information:

• Print no. of these instructions 0185.0928.0006.

• Rating plate number = number on the side of the rating

plate

• Item number from the 

unit overview [

}

 4]

.

In case of questions, please contact:

Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen, Deutschland
Tel. +49 7720 694 445
Fax +49 7720 694 175
E-mail: 

[email protected]

15 Dismantling and environmentally sound
disposal

 Old devices and electronic components may

only be dismantled by specialists with electrical
training. 

Proper disposal avoids detrimental impact on

people and the environment and allows valuable raw ma-
terials to be reused with the least amount of environ-
mental impact.

Do not dispose of the following compon-
ents in household waste!

Old devices, wearing parts (e.g. air filters),
defective components, electrical and elec-
tronic scrap, environmentally hazardous li-
quids/oils, etc. Dispose of them in an envir-
onmentally friendly manner and recycle
them at the appropriate collection points (→
Waste Disposal Act).

1. Separate the components according to material groups.

2. Dispose of packaging materials (cardboard, filling ma-

terials, plastics) via appropriate recycling systems or re-
cycling centres.

3. Observe the respective country-specific and local regu-

lations.

Company information

© Maico Elektroapparate-Fabrik GmbH.

 Translation of the

original operating instructions. Misprints, errors and tech-
nical changes are reserved. The brands, brand names and
protected trade marks that are referred to in this docu-
ment refer to their owners or their products.

Summary of Contents for EZR Series

Page 1: ...bsanleitung separates Sicher heitshinweisblatt f r Industrieventilatoren 3 Bestimmungsgem e Verwendung EZR DZR Rohrventilatoren dienen zur Ent oder Bel ftung in h uslichen oder gewerblichen Bereichen...

Page 2: ...lich ein Schutzgitter SG als Ber hrungs und Einsaugschutz anbringen 8 Geeignetes Isolations und Schalld mmungsmaterial anbringen 9 2 Elektrischer Anschluss ACHTUNG Ger tebesch digung bei Kurzschluss N...

Page 3: ...e grenzer abgek hlt sind Die Abk hlzeit kann bis zu 30 Minuten betragen Erst dann den Ventilator wieder einschalten Ventilator schaltet nicht ein Fl gelrad dreht sich nicht Fl gelrad pr fen Sicherstel...

Page 4: ...s separate safety in struction sheet for industrial fans 3 Intended use EZR DZR duct fans are used for air extraction or ventila tion in domestic or commercial areas Example Changing rooms foremen s o...

Page 5: ...Risk of damage to unit in the event of short cir cuits Insulate any unnecessary cable cores Make sure to connect the fan to an external control device with automatic latching switch off The control de...

Page 6: ...heck the fan for unusual noises during oper ation Malfunction Cause measures Deposits on the impeller and in the housing caused by dust in the air Operation without air filter Install air filter in du...

Page 7: ...rit s pa r e pour les ventilateurs industriels 3 Utilisation conforme Les ventilateurs pour gaine ronde EZR DZR sont utilis s pour l vacuation et l insufflation d air dans les zones do mestiques ou co...

Page 8: ...h it 7 En cas d aspiration libre ajouter une grille de protec tion SG contre les contacts et les risques d aspiration 8 Poser des mat riaux d isolation thermique et phonique adapt s 9 2 Branchement le...

Page 9: ...e temp rature Le temps de refroidissement peut at teindre jusqu 30 minutes Le ventilateur peut alors tre remis en marche Le ventilateur ne se met pas en marche L h lice ne tourne pas V rifier l h lice...

Page 10: ...uton Arr t S2 bouton Marche Q1 contacteur US 16 2 EZR 25 2 B Mit Sch tzschaltung selbsthaltend With contactor switching latched Avec circuit de contacteurs auto maintien S1 Aus Taster S2 Ein Taster Q1...

Page 11: ...B Mit 5 Stufentransformator TRE With TRE 5 step transformer Avec transformateur 5 plots TRE S1 Aus Taster S2 Ein Taster Q1 Sch tz US 16 S1 Off button S2 On button Q1 US 16 contactor S1 bouton Arr t S2...

Page 12: ...hzahlsteller STX STSX und Motorschutzschalter MVE 10 1 With STX STSX speed controller and MVE 10 1 motor pro tection switch Avec r gulateur de vitesse STX STSX et disjoncteur mo teur MVE 10 1 11 EZR B...

Page 13: ...ator TR With MV 25 1 motor protection switch and TR 5 step transformer Avec disjoncteur moteur MV 25 1 et transformateur 5 plots TR 3 DZR B polumschaltbar pole changeable in version de polarit Polumsc...

Page 14: ...mbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service 49 7720 6940 I info maico de 0185 0928 0006_RLF 9_05 23_DSW AS 5 DZR 25 4 D Mit 5 Stufentransforma...

Reviews: