Maico EZR Series Installation And Operating Instructions Manual Download Page 4

Montage- und Betriebsanleitung EZR ..., DZR ...
Installation and operating instructions for EZR ..., DZR ...
Notice de montage et mode d'emploi EZR ..., DZR ...

EN

4

Maico Elektroapparate-Fabrik GmbH 

I

 Steinbeisstr. 20 

I

 78056 Villingen-Schwenningen 

I

 Germany 

www.maico-ventilatoren.com

 

I

 S49 7720 6940 

I

 [email protected]

0185.0928.0006_RLF.9_05.23_DSW-AS

Installation and operating instructions

Table of contents

1

Safety ................................................................

4

2

Scope of delivery................................................

4

3

Intended use......................................................

4

4

Unit overview ....................................................

4

5

Product information ..........................................

4

5.1

Unit versions ...............................................

4

5.2

Device features ...........................................

4

5.3

Thermal overload protection......................

4

6

Technical data....................................................

5

7

Transport, storage .............................................

5

8

Installation instructions .....................................

5

9

Installation, electrical connection ......................

5

9.1

Installation ..................................................

5

9.2

Electrical connection...................................

5

10 Commissioning ..................................................

5

11 Operation ..........................................................

5

12 Cleaning, maintenance.......................................

6

13 Fault rectification...............................................

6

14 Spare parts ........................................................

6

15 Dismantling and environmentally sound dis-

posal..................................................................

6

Company information ........................................

6

EZR circuit diagrams...........................................

10

DZR circuit diagrams ..........................................

13

1 Safety

• Please read the instructions carefully before installing,

commissioning and using.

• Follow the instructions.

• Observe the 

enclosed safety instruction sheet for indus-

trial fans

 and the technical data.

• Pass these instructions on to the owner for safekeeping.

Specialist installers, qualifications, requirements

The fan may only be installed, set up, retrofitted, commis-
sioned, cleaned, serviced or repaired by 

installers special-

ised in ventilation technology

. Electrical connection, com-

missioning, maintenance and repairs may only be carried
out by a 

qualified electrician

 in accordance with DGUV

regulation 3, Section 2 (3) and in compliance with the rel-
evant standards (e.g. DIN EN 50110-1) and technical rules.
Further provisions of other national laws must be taken
into account.

Qualifications, requirements:

 Specialist training and know-

ledge of compulsory technical standards, EU Directives and
EU Ordinances. The installations must be carried out pro-
fessionally. Applicable accident prevention regulations, oc-
cupational health and safety measures (protective clothing
in good repair etc.) must be observed. Installation work by
trainees is only permitted under the supervision of the
above-mentioned trained specialists.

2 Scope of delivery

EZR

 or 

DZR

 duct fan, cable grommets in the terminal box,

for EZR additionally a capacitor in the terminal box, these
installation and operating instructions, separate safety in-
struction sheet for industrial fans.

3 Intended use

EZR/DZR duct fans

 are used for 

air extraction or ventila-

tion

 in domestic or commercial areas. Example: Changing

rooms, foremen’s offices, workshops, manufacturing
plants, machine or workplace extraction systems, indus-
trial halls, laboratories, fitness rooms, restaurants or other
commercial premises. Any other or additional use shall be
deemed improper.

Operation of the EZR or DZR is only permissible:

• for a permanent installation in indoor areas;

• if installed on a wall or ceiling with sufficient load-bear-

ing capacity;

• with permanent electrical installation;

• with 

FU

 mounting foot matching the unit variant;

• between ducts with 

EL

 or 

ELA

 flexible cuffs;

• with ducts matching the nominal size (folded spiral-

seams duct), Ø 250 to Ø 600 depending on the unit vari-
ant;

• with 

GP

 vibration dampers for vibration damping on the

duct system;

• with free contact inlets or outlets with protection

against accidental contact in accordance with EN ISO
13857, for example with the 

SGR

 protective grille.

4 Unit overview

1 End cover

2 Motor

3 Strut (3 pieces)

4 Impeller

5 End cover

6 Duct sleeve

7 Terminal box

8 Capacitor

S Sticker showing air flow and rotational direction

T Rating plate

I Air flow direction with air drawn across motor

II Rotational direction of impeller

5 Product information

5.1 Unit versions

EZR ... B, EZR 25/4 D:

 single-phase AC versions

DZR ... B, DZR 25/4 D:

 three-phase AC versions, pole-

changeable three-phase AC versions

5.2 Device features

• Duct fans with nominal diameters Ø 200 - 600 mm.

• Any installation position can be selected. Air extraction

or ventilation, depending on installation position.

• EZR/DZR are speed controllable. 

Exception: 

DZR 40/2 B

are not speed controllable.

• Reversing mode permitted. Flow rate in opposite air flow

direction reduced by around 35 %. For reversing switch
→ Internet 

www.maico-ventilatoren.com

.

• Operating capacitor for EZR fans ready for connection in

terminal box.

• EZR/DZR are configured for continuous operation.

 If the direction of rotation is changed fre-

quently, the motor may heat up impermissibly →
therefore avoid frequent changes of direction of
rotation.

5.3 Thermal overload protection

Thermal overload protection with temperature sensor in
the motor winding as a standard feature. In case of over-
load/overheating/blockage, the fan is automatically
switched off via an 

external control device

.

Exceptions:

 Overload protection for 

pole-changeable

 fans

and 

DZR 25/4 D

 varies depending on the application. Con-

tact us for more information → 

[email protected]

.

Summary of Contents for EZR Series

Page 1: ...bsanleitung separates Sicher heitshinweisblatt f r Industrieventilatoren 3 Bestimmungsgem e Verwendung EZR DZR Rohrventilatoren dienen zur Ent oder Bel ftung in h uslichen oder gewerblichen Bereichen...

Page 2: ...lich ein Schutzgitter SG als Ber hrungs und Einsaugschutz anbringen 8 Geeignetes Isolations und Schalld mmungsmaterial anbringen 9 2 Elektrischer Anschluss ACHTUNG Ger tebesch digung bei Kurzschluss N...

Page 3: ...e grenzer abgek hlt sind Die Abk hlzeit kann bis zu 30 Minuten betragen Erst dann den Ventilator wieder einschalten Ventilator schaltet nicht ein Fl gelrad dreht sich nicht Fl gelrad pr fen Sicherstel...

Page 4: ...s separate safety in struction sheet for industrial fans 3 Intended use EZR DZR duct fans are used for air extraction or ventila tion in domestic or commercial areas Example Changing rooms foremen s o...

Page 5: ...Risk of damage to unit in the event of short cir cuits Insulate any unnecessary cable cores Make sure to connect the fan to an external control device with automatic latching switch off The control de...

Page 6: ...heck the fan for unusual noises during oper ation Malfunction Cause measures Deposits on the impeller and in the housing caused by dust in the air Operation without air filter Install air filter in du...

Page 7: ...rit s pa r e pour les ventilateurs industriels 3 Utilisation conforme Les ventilateurs pour gaine ronde EZR DZR sont utilis s pour l vacuation et l insufflation d air dans les zones do mestiques ou co...

Page 8: ...h it 7 En cas d aspiration libre ajouter une grille de protec tion SG contre les contacts et les risques d aspiration 8 Poser des mat riaux d isolation thermique et phonique adapt s 9 2 Branchement le...

Page 9: ...e temp rature Le temps de refroidissement peut at teindre jusqu 30 minutes Le ventilateur peut alors tre remis en marche Le ventilateur ne se met pas en marche L h lice ne tourne pas V rifier l h lice...

Page 10: ...uton Arr t S2 bouton Marche Q1 contacteur US 16 2 EZR 25 2 B Mit Sch tzschaltung selbsthaltend With contactor switching latched Avec circuit de contacteurs auto maintien S1 Aus Taster S2 Ein Taster Q1...

Page 11: ...B Mit 5 Stufentransformator TRE With TRE 5 step transformer Avec transformateur 5 plots TRE S1 Aus Taster S2 Ein Taster Q1 Sch tz US 16 S1 Off button S2 On button Q1 US 16 contactor S1 bouton Arr t S2...

Page 12: ...hzahlsteller STX STSX und Motorschutzschalter MVE 10 1 With STX STSX speed controller and MVE 10 1 motor pro tection switch Avec r gulateur de vitesse STX STSX et disjoncteur mo teur MVE 10 1 11 EZR B...

Page 13: ...ator TR With MV 25 1 motor protection switch and TR 5 step transformer Avec disjoncteur moteur MV 25 1 et transformateur 5 plots TR 3 DZR B polumschaltbar pole changeable in version de polarit Polumsc...

Page 14: ...mbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service 49 7720 6940 I info maico de 0185 0928 0006_RLF 9_05 23_DSW AS 5 DZR 25 4 D Mit 5 Stufentransforma...

Reviews: