Maico EVN 22 Installation And Operating Instructions Manual Download Page 1

Montage- und Betriebsanleitung EVN 22, EVN 22 R
Installation and operating instructions for EVN 22, EVN 22 R
Notice de montage et mode d'emploi EVN 22, EVN 22 R

DE

1

Maico Elektroapparate-Fabrik GmbH 

I

 Steinbeisstr. 20 

I

 78056 Villingen-Schwenningen 

I

 Germany 

www.maico-ventilatoren.com

 

I

 S49 7720 6940 

I

 [email protected]

0185.0981.0006_RLF.9_07.23_DSW

EVN 22, EVN 22 R

EVN 22

EVN 22 R

Summary of Contents for EVN 22

Page 1: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R DE 1 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Page 2: ...ien Fl ssigkeiten oder Gase in der N he des Ger ts In der N he des Ger ts keine brennbaren Materialien Fl ssigkeiten oder Gase deponieren die sich bei Hitze oder durch Funkenbildung entz nden und in B...

Page 3: ...d angebrachtem Innenge h use Diese Ventilatoren sind ausschlie lich f r den h uslichen Gebrauch und hnliche Zwecke vorgesehen Eine andere oder dar ber hinausgehende Benutzung gilt als nicht be stimmun...

Page 4: ...pe die Lamellen nach oben schwenken Zum Reinigen kein aggressives ge sundheitssch dliches oder leicht entflammbares Reinigungsmittel verwenden 3 Innengeh use anbringen 10 Wartung Bei Standardbetrieb i...

Page 5: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R EN 5 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Page 6: ...any flammable materials liquids or gases near the unit which may ignite in the event of heat or sparks and catch fire DANGER Explosive gases and dust may ignite and cause serious explosions or fire N...

Page 7: ...c tifying the fault the fan can restart automatically 6 Technical data Ambient conditions Permissible maximum temperature of air medium 40 C Sufficient supply air intake must be ensured during oper at...

Page 8: ...re it against being switched on again Have the connection cable replaced by a trained specialist 11 Fault rectification Fault finding and repairs only permissible when carried out by qualified electri...

Page 9: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R FR 9 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Page 10: ...ormes techniques des directives et ordonnances de l UE sont prescrites Les ins tallations doivent tre r alis es dans les r gles de l art Les consignes de pr vention d accident en vigueur les me sures...

Page 11: ...arable dans lesquels sont install s des foyers d pendant de l air ambiant que si des dispositifs de s curit emp chent le fonctionne ment simultan de foyers d pendant de l air ambiant pour des combusti...

Page 12: ...r conform ment au sch ma de branchement autocol lant dans la bo te bornes ou chapitre Sch mas de branchement 14 Pour EVN 22 R raccorder en plus le c ble de raccordement du volet ext rieur 2 Raccorder...

Page 13: ...hwenningen Allemagne T l 49 7720 694 445 Fax 49 7720 694 175 E mail ersatzteilservice maico de 13 D montage et limination dans le respect de l environnement Les appareils usag s et composants lectriqu...

Page 14: ...lectrique ext rieur S1 marche arr t S2 Commutation insufflation vacuation d air bornes 4 et 5 insufflation vacuation d air EVN 22 R FS6 FS7 Elektrische Verschlussklappe au en S1 Ein Aus S2 Umschaltung...