Maico ERK 100 Mounting And Operating Instructions Download Page 3

1. Scope of delivery 

  ERK duct fan including mounting foot 

(pre-installed) 

  Accessories bag containing fastening 

material  
(4 fastening screws and 4 dowels) in the 
terminal box 

  Mounting and operating instructions 

 

2. General notes 

  

 

Read these installation and 
operating instructions carefully 
before using the fan for the first 
time. Follow the instructions. Keep 
these instructions safe for use later 
on. 

 

Summary of Contents for ERK 100

Page 1: ...Duct fans ERK 100 ERK 100 T ERK 100 S ERK 100 ST ERK 125 ERK 125 T ERK 150 ERK 160 ERK 200 Mounting and operating instructions www m aico ventilatoren c om VENTILATOREN...

Page 2: ...peed control with speed controller 9 8 4 Operation with step transformer 10 8 5 Commissioning 10 9 Maintenance 10 10 Fault rectification 10 11 Dismantling 12 12 Disposal 12 13 Wiring diagrams 12 Addit...

Page 3: ...g fastening material 4 fastening screws and 4 dowels in the terminal box Mounting and operating instructions 2 General notes Read these installation and operating instructions carefully before using t...

Page 4: ...50 DN 160 or DN 200 ERK 100 T ERK 125 T like ERK also with follow up relay timer adjustable from 3 to 15 minutes Units with nominal size of DN 100 or DN 125 ERK 100 S ERK 100 ST Duct fans with guide v...

Page 5: ...e permitted for the duct The ERK fan must be permanently installed and the electrical supply cable permanently laid A mounting foot 5 should be used for installation The mounting location must demonst...

Page 6: ...itionally a mains isolation device with contact openings of at least 3 mm at each pole must be installed Only operate the unit when it is completely installed Ensure that foreign bodies cannot be suck...

Page 7: ...ly store fan horizontally in a suitable dry room ambient temperature 10 to 60 C Before installing check that the motor bearing is working properly Maico accepts no liability for corrosion damage cause...

Page 8: ...ctly in the clamp grooves in order to prevent leakages 5 Fit suitable insulation sound deadening and installation material 8 2 Electrical connection DANGER Danger to life from electric shock Prior to...

Page 9: ...T units set the unit overrun time with potentiometer 9 setting range 3 to 15 minutes 8 Fit optional on off switch 9 Connect other optional accessory components chapters 8 3 and 8 4 NOTICE Unit damage...

Page 10: ...lt Repairs should only be carried out by a trained electrician DANGER Danger to life from electric shock Prior to accessing the connection terminals switch off all supply circuits Switch off the mains...

Page 11: ...If the fault still continues or occurs again disconnect the fan from the power supply at all poles Let a certified electrician determine the cause of the fault and eliminate it i...

Page 12: ...rning sign 1 Switch off mains fuse secure and fit warning sign 2 Remove folded spiral seam ducts from fan 3 Remove the terminal box cover 4 Remove all cables 5 Remove fan 12 Disposal Do not dispose of...

Page 13: ...13 Wiring diagrams en 13 ERK 100 T ERK 100 ST ERK 125 T ERK 200...

Page 14: ...de gb Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 0 7720 694 447 technik maico de 07 14_Es 0185 1173 0000_RLF 4_07 14_DSW...