22. Wiring diagrams
33
22. Wiring diagrams
Tolerances for the times stated
below = nominal value + 20 %.
ER 60 E, ER 100 E
S1 On/Off switch
S1= On/Off switch
➀
= Main room
➁
= Second room
ER 60 EVZ
ER 100 EVZ
Standard switching Switching options
S1 = On/Off
switch
(ON after approx.
50 seconds)
➀
= Main room
➁
= Second
room
ER 60 E and ER 100 E
The fan starts up after switching on the room
lighting (with switch S1). The fan also
switches off after the room lighting has been
turned off.
ER 100 E with main and second room
connection
The fan starts up after switching on the room
lighting (with switch S1). The fan also
switches off after the room lighting has been
turned off.
ER 60 EVZ, ER 100 EVZ
Standard switching:
The fan starts up approximately 50 seconds
after the room lighting is switched on. The fan
has an overrun time of 15 minutes after
switching off.
Switching option
The fan starts up approx. 50 seconds after
switching on the room lighting (with switch S1
and S2).
The fan has an overrun time of 15 minutes
after switching off with switch S1. In addition,
the fan can be switched off with switch S2
independent of the room lighting.
ER 100 EVZ with main and second room
connection
The fan starts up approx. 50 seconds after
switching on the room lighting (with one
switch). The fan has an overrun time of
15 minutes after switching off with the last
switch to have been used.