16. Cleaning, maintenance
28
16. Cleaning, maintenance
The unit is practically maintenance-free. The
air filter simply needs replacing every 3 to 6
months, depending on the degree of soiling.
DANGER
Danger to life from electric shock.
Prior to accessing the connection
terminals, switch off all supply circuits.
Switch off mains fuse, secure against
being accidentally switched back on and
position a visible warning sign.
NOTICE
The unit will be damaged if incorrect
cleaning agent is used.
Do not use aggressive cleaning agents
.
1. Only use a dry cloth to clean the cover [7]
of the fan.
2. If the cover is very dirty, remove it and
clean with water.
3. Fold up cover [7].
4. Take out filter mat [10] and replace it.
5. Place filter mat on intake grille cover [7]
and lock cover. The lock must engage
audibly.
Filter change interval every 3
to 6 months, depending on the
degree of soiling.
Filter mats ZF 60/100:
Pack of 5, filter class G2
in accordance with EN 779,
Art. no. 0093.0680
Filter-Shop:
www.ventilatorshop24.com
16.1 Filter change
7 Cover
10 Filter mat, filter class G2
In case of questions, please contact: