Maico ER EC RF17 Installation And Operating Instructions Manual Download Page 8

11 Wiring diagrams

8

5. Run function test: Test all unit functions (over-

run time, interval, humidity control etc.)

For ER-A, no setting functions. For ER-AK,
ER-AH, ER-AB, the operating parameters
can be changed.

6. Fold down the upper part of the cover (upper

part must audibly engage).

11 Wiring diagrams

Cut off and insulate PE conductor and individual cable cores that are not required

Nominal load can be
switched without base load

Nominal load can be
switched with permanent
base load

Nominal load and base load
can be switched

Please tick the connection variant

Nominal load switchable with
2 cable cores*

Base load switchable with 2
cable cores*

*If the units are connected with 2 cable cores
(nominal load switchable with 2 cable cores, base
load switchable with 2 cable cores), the ER-A
cover is to be used. The ER-AK, ER-AH and ER-
AB covers require a permanent electrical connec-
tion.

12 Dismantling

Dismantling is only permissible by persons with
electrical training.

13 Environmentally responsible
disposal

Once they are no longer needed, packaging ma-
terials and used units should be disposed of in
compliance with local regulations. Do not dispose
of old units in the normal household waste.

Summary of Contents for ER EC RF17

Page 1: ...Installation and operating instructions ER EC flush mounted exhaust air systems according to DIN 18017 3 ER EC RF17 www maico ventilatoren com...

Page 2: ...ty instructions for electrics 5 7 Technical data 5 8 Preparation for installation 5 9 Electrical connection and installation of the fan insert 6 9 1 Electrical connection of the fan in sert 6 9 2 Inst...

Page 3: ...le operation The unit must not be used in the following situations under any circumstances DANGER Risk of combustion fire from flammable materials liquids or gases in the vicinity of the unit Do not p...

Page 4: ...e are no air filters Heavily soiled or moist air filters can accumulate harmful substances mould germs etc This may also happen if the unit is shut down for an extended period If the air filter is mis...

Page 5: ...J cables depending on the unit variant 3 x 1 5 mm or 5 x 1 5 mm Units may only be operated using the voltage and frequency shown on the rating plate Unit may be energized even when at a standstill an...

Page 6: ...de the housing the fan insert cannot be installed correctly The power cable may be damaged when inserting the fan unit Do not cut the power cable inside the housing too short Risk of damage to unit in...

Page 7: ...n angle 1 Mount the fixing cover included in the scope of delivery at the bottom left with the respect ive fillister head screw 2 For ER A continue with step 3 For ER AK ER AH ER AB plug cover s flat...

Page 8: ...and base load can be switched Please tick the connection variant Nominal load switchable with 2 cable cores Base load switchable with 2 cable cores If the units are connected with 2 cable cores nomina...

Page 9: ...Notes...

Page 10: ......

Page 11: ......

Page 12: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Deutschland Service 49 7720 6940 info maico de D01 21_EN_AS AV...

Reviews: