7. Product information
11
● Energy-saving motor with thermal overload
protection. This switches itself off in the
event of overheating and then back on
again automatically after cooling down.
● The fans may be subject to jet water in
areas 1 and 2 (DIN VDE 0100-701:
2008-10 and/or HD 60 364-7:2007).
7.3.3 ER-UP controls (circuit board types)
ER-UP fans are available in various models
and with various unit properties. These
depend on the control/circuit board type
used in the fan insert [3].
The circuit variants and functions
suited to the circuit board type are
described in chapter 22.
Circuit board models
●
EVZ model
: With start delay and overrun
time.
●
EG model
: With base load circuit.
Continuous operation at 35 m³/h, high
speed (full load) can be switched with
optional switch.
●
EH model
: Barrier-free. With humidity
control (fully automatic). Overrun time
controlled by program (15 minutes at full
load). Can also be operated manually with
optional switch. Not suitable for second
room ventilation.
Unit type
Circuit board
type
Start delay
[s]
Overrun
time
[min]
Can be
controlled
by speed
Power
cable
[mm²]
ER 60 E
Standard board
no
3 x 1.5
ER 100 E
Standard board
yes
3 x 1.5
ER 60 EVZ, ER 100 EVZ
VZ board
50
15
no
5 x 1.5
ER 60 EG, ER 100 EG
G board
no
5 x 1.5
ER 60 EH, ER 100 EH
H board
15
no
5 x 1.5
Tolerance of time details max. + 20 %.