4. Safety instructions and warnings │ UK 

 

11 

The fan unit 

must

 

not

 be used in the follo-

wing situations 

under any circumstances. 

 Risk of combustion/fire from flam-

mable materials, liquids or gases in 

the vicinity of the fan. 

Do not place 

any flammable materials, liquids or gases 

near the fan, which may ignite in the event of 

heat or sparks and catch fire. 

 

Explosive gases and dusts may 

ignite and cause serious explosions 

or fire.

 Never use fan unit in an 

explosive atmosphere (risk of explosion). 

 

Risk from operating in single air 

extraction systems in accordance 

with DIN 18017-3

. Fan does not satisfy 

the DIN 18017-3 standard. Do not use fan in 

systems in accordance with DIN 18017-3. 

 

Risk to health from chemicals or 

aggressive gases/vapours. 

Chemicals 

or aggressive gases/vapours may harm 

health, especially if they are distributed 

throughout the rooms by the fan. Never use 

fan to convey chemicals or aggressive 

gases/vapours. 

 

Grease and oil vapours from range 

hoods may contaminate the fan and 

ventilation ducts and reduce efficiency. 

Never use fan to convey greasy air, e.g. in 

combination with range hoods with exhaust 

air operation. 
 

Read all the safety instructions. 

 

Risks for children and people 

with reduced physical, 

sensory or mental capabilities 

or a lack of knowledge. 

Fan 

may only be installed, 

commissioned, cleaned and 

maintained by people who can 

safely recognise and avoid the 

risks associated with this work. 

 

Danger of injury due to 

suction from fan and 

rotating impeller.

 Hair, 

clothing, jewellery etc. may be 

pulled into the fan if you get too 

close to it. During operation 

always keep far enough away to 

prevent this from happening.

 

 

Danger of injury if foreign 

bodies are inserted into 

the unit. 

Do not insert any 

objects in the unit. 

 

A fan that is not installed correctly 

may result in non-intended operation 

or impermissible operation. 

Operation 

is only permitted with a correct installation 

position, with mounted cover [4] and outer 

protective grille. The fan may be operated 

only if the protec-tion against accidental 

contact with the impeller is guaranteed to be 

in accordance with EN 13857. 

 

Risk of injury and health risk in the 

event of changes or modifications  

or if components which are not 

permitted are used. 

The unit may only be 

operated with original components. Changes 

and modifications are not permitted and 

release the manufacturer from any guarantee 

obligations and liability,

 e.g. if the unit is 

drilled at a point which is not permitted.

 

 

Danger of injury when working at 

heights.

 Use appropriate climbing aids 

(ladders). Stability should be ensured,  

if necessary have the ladders steadied by a 

2nd person. Ensure that you are standing 

securely and cannot lose your balance and 

that there is no one under the unit. 
 

Summary of Contents for ECA piano H

Page 1: ...Kleinraumventilatoren Mounting and Operating instructions Small room fans Instructions de montage et Mode d emploi A rateurs pour petites pi ces ECA piano STANDARD ECA piano TC ECA piano H B www m ai...

Page 2: ...2...

Page 3: ...der Elektrik d rfen nur von einer Elektrofachkraft vorgenommen werden Sie sind eine Elektrofachkraft wenn Sie aufgrund Ihrer fachlichen Ausbildung Schulung und Erfahrung die einschl gigen Normen und...

Page 4: ...shauben k nnen den Ventilator und die Luftleitungen verschmutzen und die Leistungsf higkeit reduzieren Ventilator auf keinen Fall zur F rderung fetthaltiger Luft verwenden z B in Kombination mit Dunst...

Page 5: ...le Versorgungs stromkreise abschalten Netzsicherung ausschalten und gegen Wiedereinschalten sichern Ein Warnschild sichtbar anbringen Bei der Elektroinstallation die geltenden Vorschriften beachten z...

Page 6: ...k ca 12 min Umgebungsbedingungen und 6 Grenzen f r den Betrieb Zul ssige H chsttemperatur des F rder mediums 40 C St rfestigkeit nach EN 55014 2 je nach Impulsform und Energieanteil 1000 bis 4000 V Be...

Page 7: ...tel 8 1 beschrieben vornehmen 8 4 Geh use 1 ACHTUNG Ger tebesch digung Funktionsst rung bei streifendem Fl gelrad 7 Ger t weder verspannt noch gequetscht einbauen F r ebenen Untergrund sorgen 1 Geh us...

Page 8: ...auch Positionen P in Abb A ECA piano TC Poti P Nachlaufzeit ab Werk ca 6 Minuten 9 00 Uhr ECA piano H Poti P1 Nachlaufzeit ab Werk ca 12 Minuten 12 00 Uhr ECA piano H Poti P2 Feuchteschaltpunkt ganz l...

Page 9: ...h Abk hlung selbstt tig wieder ein Ventilator schaltet nicht aus oder Ventilator schaltet ungewollt ein Durch eine Glimmlampe im Kontrollschalter parallel ver legte Leitungen Induktion oder Transforma...

Page 10: ...electrician is permitted to work on the electrics You are deemed a trained electrician if you are familiar with the relevant standards and guidelines can competently and safely connect units to an ele...

Page 11: ...wledge Fan may only be installed commissioned cleaned and maintained by people who can safely recognise and avoid the risks associated with this work Danger of injury due to suction from fan and rotat...

Page 12: ...ating plate The degree of protection stated on the rating plate is only guaranteed if installation is undertaken correctly and if the connection cable is correctly guided through the cable grommet The...

Page 13: ...ion Connect a X2 capacitor 220 nF 250 V against neutral lead in case of a switch with negative glow lamp The capacitor is to be provided by the customer Storage Store unit exclusively in a dry locatio...

Page 14: ...ring 5 is present at the rear of the housing and that it is seated correctly 2 ECA piano STANDARD ECA piano TC If necessary supply additional material e g foam strip to fix the unit to the wall or du...

Page 15: ...rox 12 minutes 12 o clock ECA piano H potentiometer P2 Humidity switching point setting to the far left approx 50 r h 12 o clock see figure approx 70 r h factory setting setting to the far right appro...

Page 16: ...tch negative glow lamp parallel installed wires mutual induction or transformers respectively other electrical parts Recommendation Connect a X2 capacitor 220 nF 250 V against neutral lead Dismantling...

Page 17: ...p rience dans la technique de ventilation est autoris effectuer le montage Les travaux sur le syst me lectrique ne doivent tre ex cut s que par des lectriciens qualifi s On entend par lectricien quali...

Page 18: ...ifs risquent de nuire la sant notamment s ils sont diffus s dans les pi ces par le ventilateur Ne jamais utiliser le ventilateur pour diffuser des produits chimiques ou gaz vapeurs agressifs Des vapeu...

Page 19: ...ant de retirer le cache de l lectronique couper tous les circuits d alimentation lectrique d sactiver le fusible secteur s curiser contre toute remise en service intempestive et apposer un panneau d a...

Page 20: ...nt par l interrupteur d clairage Si l humidit relative est sup rieure au point de commutation il est impossible d arr ter le ventilateur m me avec l interrupteur d clairage Le ventilateur s arr te si...

Page 21: ...e le c ble secteur encastr jusqu au lieu de montage Pour les carte ments voir ci dessus Ce faisant faire sortir le c ble secteur d au moins 110 mm du mur 8 2 Plafond 1 Pr parations de montage comme d...

Page 22: ...se R gler toujours la vitesse de rotation minimale sur le r gulateur de vitesse de sorte que le moteur red marre apr s une panne de courant La technique de r glage par redres sement l entr e des phase...

Page 23: ...secteur s curiser contre toute remise en service intempestive et apposer un panneau d avertissement 2 Si le cache 4 est tr s sale le retirer avec pr caution du ventilateur chap 13 et le nettoyer avec...

Page 24: ...e l appareil du secteur couper le fusible secteur le prot ger contre toute remise en service intempestive et apposer un panneau d avertissement de mani re bien visible 2 Tirer d abord le cache 4 dans...

Page 25: ...25 Schaltbilder 15 ECA piano STANDARD ECA piano TC ECA piano H Variante 1 Variante 2 15 Schaltbilder Wiring diagrams Sch mas de branchement...

Page 26: ...26...

Page 27: ...27...

Page 28: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 technik maico de 04 18_Es 0185 1111 0005_RLF 7_04 18_DSW...