Maico ECA 120 VZ Installation Instructions Manual Download Page 4

INSTALLATION INSTRUCTIONS

ECA 120 VZ

Version: 2018-01-25 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 4

1

AP Shutter for air extraction.

2

WH wall sleeve

3

ECA small room fan

4

MLK 45 door ventilation grille

Wall mounting of ECA small room fans

Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a

wall:

A minimum distance between the wall and the ceiling must be observed when preparing the wall breakthrough, see dia-

gram.

Fit a wall sleeve.

Feed in the connecting cable for surface or recessed mounting.

ECA 100 ipro and ECA piano only available as recessed-mounted fans.

Secure the fan using screws during installation.

The AP shutter prevents cold air from entering when the fan is switched off. Not required with ECA piano and all versions

with electrically-operated internal shutter.