10. Fault rectification
│
EN
21
Fault
Cause, Measure
Fan does not
switch off
or
fan switch on
accidentally.
A high-impedance voltage
applies against terminal L1
with a control switch negative
glow lamp, parallel installed
wires (mutual induction) or
transformers respectively
other electrical parts.
Recommendation: Connect a
X2-capacitor (220 nF/250 V)
against neutral lead.
11. Dismantling
Dismantling may only be undertaken
by an electrician.
DANGER
Danger to life from electric
shock.
Switch off mains fuse before
removing.
CAUTION
Danger of burning due to
contact with bimetal (K units).
Bimetal [5.3] is very hot after fan
is switched off. Do not touch.
Cool-down time can be up to
10 minutes
.
1. Unlock covers (see arrow) and remove.
2. Remove electronics cover [4] (3 latches).
3. Remove power cable.
4. Remove fan.
12. Disposal
Not in domestic waste
. The unit
contains in part material that can be
recycled and in part substances that
should not end up as domestic
waste.
Dispose of the unit once it has reached the
end of its working life according to the regu-
lations valid where you are.