10. Operation
The following table shows the performance
levels of the master and slave fans that are
assigned to the different RLS RC system
levels.
Performance level 1 = 78 m³/h
Performance level 2 = 92 m³/h
(Free outlet specifications)
Program selection
Program
Apartment size
P1
30 m² / 50 m² / 70 m²
P2
90 m² / 110 m² / 130² / 140 m²
ECA 100 ipro RC
The fan is switched on/off either at the RLS
RC room air control, with the DS RC radio
switch, or with a window radio contact to be
supplied by the customer.
For the function of radio components
Maico Smart System Description
Chapter 3.4.
ECA 100 ipro RCH
The unit is barrier-free. Air extraction is
executed according to automatic humidity
operation. If there is little humidity, the unit
switches off completely.
For manual operation via radio
components,
ECA 100 ipro RC.
11. Maintenance
The unit is maintenance-free.
12. Cleaning
DANGER
Danger to life. Unit is
powered up.
Switch the mains fuse off.
NOTICE
Risk of damage to unit if
incorrect cleaning agent is
used.
Only use water to clean cover [6]
and designer cover [7]. Do not
use aggressive cleaning agents.
Only use a dry cloth to clean the internal
1.
parts of the fan.
If the designer cover [7] is very dirty, remove
2.
it carefully from the fan (
fold-out page,
Fig. B) and clean with water.
Fit designer cover [7].
3.
13. Fault rectification
● Call on the services of a trained electrician
any time there is a fault.
● Repairs should only be carried out by a
trained electrician.
DANGER
Danger to life. Unit is
powered up.
Switch off at the
mains fuse before starting work
on the electrical connection and
position a sign warning against
switching it back on.
RLS RC program for
ECA 100 ipro RC and
ECA 100 ipro RCH
System
level 0
System
level 1
System
level 2
System
level 3
Program P1
Master
Off
Perform. level 1
Perform. level 1
Perform. level 2
Slave(s)
Off
Off
Perform. level 1
Perform. level 1
Program P2
Master
Off
Perform. level 2
Perform. level 1
Perform. level 2
Slave(s)
Off
Off
Perform. level 1
Perform. level 2