10 Operation
30
4. Press the teach-in button (≥ 5 seconds) until
the LED on the fan lights up
once
for approx.
1 second.
ð
The setting is saved.
10 Operation
ECA 100 ipro RC
The units are switched on/off either on the RLS
RC room air control, with the DS RC radio switch,
or with a window radio contact to be provided by
the customer.
ECA 100 ipro RCH
The unit is barrier-free. Air extraction takes place
according to the automatic humidity function. If
there is little humidity, the unit switches off com-
pletely.
Program
Apartment size
P1
30 m² / 50 m² / 70 m²
P2
90 m² / 110 m² / 130² /
140 m²
Table 1:
Program selection
RLS RC pro-
gram for
ECA ...ipro RC/
KRC/RCH/
KRCH
Sys-
tem
level 0
Sys-
tem-
stufe1
Sys-
tem
level 2
Sys-
tem
level 3
Pro-
gram P1
Master Off
Power
level 1
Power
level 1
Power
level 2
Slave(
s)
Off
Off
Power
level 1
Power
level 1
Pro-
gram P2
Master Off
Power
level 2
Power
level 1
Power
level 2
Slave(
s)
Off
Off
Power
level 1
Power
level 2
Table 2:
Single-type system
Power level 1= 78 m³/h
Power level 2= 92 m³/h
(Details with free outlet)
RLS RC pro-
gram for
mixed sys-
tem ECA …
ipro RC/RCH
+ ER 100 RC
System
level 0
Sys-
tem
level 1
Sys-
tem
level 2
Sys-
tem
level 3
Pro-
gram
P1
Mas-
ter
ECA
Off
Power
level 1
Power
level 1
Power
level 2
Slave
ECA
Off
Power
level 0
Power
level 1
Power
level 1
Slave
ER
Off
Power
level 1
Power
level 1
Power
level 2
Pro-
gram
P2
Mas-
ter
ECA
Off
Power
level 2
Power
level 1
Power
level 2
Slave
ECA
Off
Power
level 0
Power
level 1
Power
level 2
Slave
ER
Off
Power
level 1
Power
level 2
Power
level 2
Table 3:
Mixed system:
ECA: Power level 1 = 78 m³/h / Power level 2 =
92 m³/h
ER: Power level 1 = 35 m³/h / Power level 2 =
60 m³/h / Power level 3 = 100 m³/h
(Details with free outlet)
11 Maintenance
The unit is maintenance-free.
12 Cleaning
Clean fan regularly, especially after it has
not been used for a long time.
NOTICE Risk of damage to unit if incorrect
cleaning agent is used.
Only clean the cover using water.
Do not use aggressive cleaning agents.
NOTICE Lamellae may break if cleaned incor-
rectly.
Be careful when cleaning them.
Do not open, close or bend the lamellae too
much.
1. Only use a dry cloth to clean the internal parts
of the fan.
2. If the cover is very dirty, carefully remove it
and clean with water.