Maico ECA 100 ipro KF Product Manual Download Page 4

 

Montage- und Betriebsanleitung

 

Kleinraumventilatoren

 

 

Mounting and Operating instructions

 

Small room fans

 

 

Instructions de montage et Mode d’emploi

 

Aérateurs pour petites pièces

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECA 100 ipro 

     

ECA 100 ipro VZC 

    

ECA 100 ipro F 

    

ECA 100 ipro H 

    

ECA 100 ipro B 

    

ECA 100 ipro K 

     

ECA 100 ipro KVZC 

    

ECA 100 ipro KF 

    

ECA 100 ipro KH 

    

ECA 100 ipro KB 

 

w w w . m a i c o - v e n t i l a t o r e n . c o m  

 

   

DE 

 

 

EN 

FR 

Summary of Contents for ECA 100 ipro KF

Page 1: ...com Druckfehler Irrt mer und technische nderungen vorbehalten DOKUMENTATION Artikelnummer 0084 0207 Kurzinformation Zweistufiger Kleinraumventilator mit elektrischem Innenverschluss und Lichtsteuerun...

Page 2: ...rvolumen 78 m h 92 m h Drehzahlsteuerbar Reversierbarkeit Spannungsart Wechselstrom Bemessungsspannung 230 V Netzfrequenz 50 Hz Nennleistung 10 W 13 W IMax 0 08 A Schutzart IP X5 Netzzuleitung 3 1 5 m...

Page 3: ...100 ipro KF Stand 15 12 2015 MAICO VENTILATOREN www maico ventilatoren com Druckfehler Irrt mer und technische nderungen vorbehalten Seite 2 Kennlinie 1 Leistungsstufe 1 2 Leistungsstufe 2 Ma zeichnun...

Page 4: ...ons Small room fans Instructions de montage et Mode d emploi A rateurs pour petites pi ces ECA 100 ipro ECA 100 ipro VZC ECA 100 ipro F ECA 100 ipro H ECA 100 ipro B ECA 100 ipro K ECA 100 ipro KVZC E...

Page 5: ...tilatoren com Mounting an Operating instructions Page 12 Wiring diagrams Page 33 Scope of delivery Small room fan ECA 100 ipro Electronics cover Sensor only for models F H and B Foam strip Installatio...

Page 6: ...A B C...

Page 7: ...Benutzung des Ventilators auf merksam durch Folgen Sie den Anweisungen Bewahren Sie diese Anleitung f r einen sp teren Gebrauch gut auf 1 1 Installationspersonal Montage nur durch Fachkr fte zul ssig...

Page 8: ...it Lichtsensor Einschaltverz gerung und Nachlaufzeit Einschalthelligkeit am Ger t min 30 Lux Ausschalthelligkeit am Ger t max 1 7 Lux H und KH Ausf hrung mit Feuchte steuerung vollautomatisch Einschal...

Page 9: ...hste Priorit t und steuert das Ger t wie zuvor beschrieben 2 3 Bestimmungsgem e Verwendung Dieses Ger t ist ausschlie lich f r den Hausgebrauch und hnliche Zwecke vorgesehen Das Ger t dient zur Entl f...

Page 10: ...st nden im Fl gel rad Keine Gegenst nde in das Ger t hineinstecken Verletzungsgefahr durch sich drehendes Fl gelrad Nicht zu nahe an das Ger t gehen damit Haare Kleidung oder Schmuck nicht in das Ger...

Page 11: ...tageort verlegen Abstandsma e siehe oben Dabei die Netzleitung mindestens 110 mm aus der Wand herausf hren 6 2 Decke ACHTUNG Kurzschlussgefahr und Ger tebesch digung durch Kondenswasserbildung im Vent...

Page 12: ...h besser biegen und Elektronikabdeckung 4 korrekt aufsetzen Leitungst lle 3 fachgerecht anbringen ggf bauseitig abdichten 5 Leitungst lle 3 in Geh use einsetzen Netzleitung so in den Anschlussraum f h...

Page 13: ...pitel 13 angeschlossenem Licht schalter ist eines der 4 nachfolgenden Betriebsprogramme einstellbar Wird dieses eingeschaltet hat es Vorrang vor der Feuchteautomatik Komfortprogramm Auslieferungszusta...

Page 14: ...n Ausklappseite Abbildung B 7 4 Inbetriebnahme 1 Netzsicherung einschalten 2 Funktionstest durchf hren 7 5 Einschaltverz gerung und Nachlaufzeit Beim ersten Dr cken der Einstell taste wird der aktuell...

Page 15: ...eine Netzspannung Pr fen ob die Netzsicherung aus gefallen ist Diese ggf einschalten Ventilator schaltet nicht ein Laufrad blockiert Nur durch Fachkraft zul ssig Abdeckung 6 abnehmen Innengitter 5 1 o...

Page 16: ...5 3 ist nach Ausschalten des Ventilators sehr hei Die Abk hlzeit kann bis zu 10 Minuten betragen 1 Abdeckungen entriegeln Pfeil und abnehmen 2 Elektronikabdeckung 4 entfernen 3 Rastnasen 3 Netzleitun...

Page 17: ...low the instructions Keep these instructions safe for use later on 1 1 Installation staff Installation is only permitted when carried out by trained specialists Electrical connections and repairs only...

Page 18: ...overrun time F and KF Model with light sensor start delay and overrun time Switch on intensity at fan min 30 lux Switch off intensity at fan max 1 7 lux H and KH Model with humidity control fully auto...

Page 19: ...t as described above 2 3 Intended use This device is only intended for domestic use and similar purposes Fan for or extracting air from bathrooms toilet rooms storage rooms showrooms offices fitness s...

Page 20: ...on Danger of injury caused by objects in the impeller Do not insert any objects in the fan unit Danger of injury from rotating impeller Do not get too close to the fan unit to avoid hair clothing or j...

Page 21: ...power cable recessed up to place of installation see above for spacing Guide the power cable at least 110 mm from the wall 6 2 Ceiling NOTICE Danger of short circuits and damage to unit if conden sati...

Page 22: ...ronics cover 4 can be positioned correctly Fit cable grommet 3 correctly seal on both sides if required 5 Insert cable grommet into housing Guide power cable into connection area such that the cable g...

Page 23: ...J4 and J5 and the light switch connected in accordance with chapter 13 If this is switched on it takes priority over the automatic humidity process Comfort program supplied in this mode night program...

Page 24: ...ter 7 5 7 Fit designer cover 7 fold out page Fig B 7 4 Start up 1 Switch the mains fuse on 2 Carry out a function test 7 5 Start delay and overrun time When the setting button is pressed for the first...

Page 25: ...ion Fault Cause Measure Fan does not switch on Start delay max 120 seconds Wait for the start delay and reduce if necessary Chap 7 5 Fan does not switch on No mains voltage Check whether the mains fus...

Page 26: ...an DANGER Danger to life from electric shock Switch off mains fuse before removing CAUTION Danger of burning due to contact with bimetal K units Bimetal 5 3 is very hot after fan is switched off Do no...

Page 27: ...e manuel d utilisation et de montage avant la premi re utilisation du ventilateur Suivez les instructions Conservez soigneusement ce manuel pour pouvoir le consulter ult rieurement 1 1 Installateurs M...

Page 28: ...ec capteur de lumi re temporisation de d marrage et dur e de fonctionnement par temporisation Lumino sit de mise en marche d arr t au niveau de l appareil min 30 lux max 1 7 lux H et KH version avec c...

Page 29: ...du temps de fonctionnement par inertie r siduel Ensuite la priorit revient au contr leur d humidit qui commande l ap pareil comme d crit pr c demment 2 3 Utilisation conforme Cet appareil est con u u...

Page 30: ...ns une ouverture de contact de 3 mm sur chaque p le est n cessaire Utiliser exclusivement l appareil la tension et la fr quence indiqu es sur la plaque signal tique N effectuer aucune modifica tion su...

Page 31: ...ts minimaux prescrits entre le mur et le plafond selon l illustration 1 Assurer un support plan autour de l appareil 2 Pratiquer une perc e dans la paroi ou percer des avant trous Diam tre minimal 105...

Page 32: ...aine murale TOP dessus 2 Aligner le bo tier horizontalement et signaler les deux trous pour cheville fl che 3 Retirer le bo tier 1 percer des trous pour chevilles M6 de 6 mm et enfoncer les chevilles...

Page 33: ...te 3 Raccorder lectriquement le c ble secteur sur le crampon lastique 13 selon l illustration du sch ma de raccordement 14 Voir aussi les illustrations de commutation du chapitre 13 Les appareils ECA...

Page 34: ...iveau de puissance 2 lors du fonc tionnement et du fonctionnement par temporisation J4 pont J5 ouvert 2 Mettre en place le cache de l lectronique ATTENTION Risque de court circuit et d endommagement d...

Page 35: ...la dur e de temporisation de d marrage d sir e s allume Attendre jusqu ce que le voyant LED clignote deux fois avant de s teindre La valeur est alors enregistr e 3 R gler la dur e de fonctionnement p...

Page 36: ...se met pas en marche La turbine est bloqu e Intervention devant tre uniquement r alis e par un sp cialiste Retirer le cache 6 D bloquer la grille int rieure 5 1 ou la fermeture int rieure 5 2 via les...

Page 37: ...DANGER Risque d lectrocution Couper le fusible secteur avant le d montage PRUDENCE Danger de br lure en cas de contact avec le bilame appareils de la s rie K Le bilame 5 3 est tr s chaud apr s mise h...

Page 38: ...lder ECA 100 ipro ECA 100 ipro K Nenndrehzahl hohe Stufe Nominal speed high level R gime nominal de niveau lev ECA 100 ipro ECA 100 ipro K Nenndrehzahl niedrige Stufe Nominal speed low level R gime no...

Page 39: ...faible ECA 100 ipro mit with avec ST1 STU1 ECA 100 ipro K mit with avec ST1 STU1 Drehzahl mit ST1 STU1 einstellbar Rotating speed adjustable with ST 1 STU 1 Vitesse r glable avec ST1 STU1 ST1 Drehzah...

Page 40: ...13 Schaltbilder Wiring diagrams Sch mas de branchement FR EN DE 35 ECA 100 ipro VZC ECA 100 ipro KVZC ECA 100 ipro H ECA 100 ipro KH ECA 100 ipro F ECA 100 ipro KF ECA 100 ipro B ECA 100 ipro KB...

Page 41: ...de gb Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 694 447 technik maico de 0185 1133 0002_RLF 4_11 14_DSW...

Page 42: ...ng Ablagerungen an den Schaufeln oder Fl gelbl ttern haben Unwucht unruhigen Lauf und Be sch digungen der Motorlager zur Folge Die Ventilatoren sind auf ruhigen Lauf ersch tterungsfreien Lauf in Zeita...

Page 43: ...erf gt Bei Einphasenmotoren ist serienm ig ein thermischer berlastungsschutz eingebaut Kanalventilatoren haben serienm ig Thermokontakte Alle Ex Ger te au er Typ ERM sowie EZQ 20 4 E Ex e haben Kaltle...