background image

 

 

Montage- und Betriebsanleitung

 

Elektro-Lufterhitzer

 

 

Mounting and Operating instructions

 

Electric air heater

 

 

Instructions de montage et Mode d’emploi

 

Réchauffeur d’air électrique

 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

ERH 10-04 

   

ERH 12-1 

   

ERH 16-2 

   

ERH 20-2 

   

ERH 25-2 

 

   

DRH 16-5 

   

DRH 20-5 

   

DRH 25-6 

   

DRH 31-6 

www.maico-ventilatoren.com 

www. m ai c o-vent i l at oren. c om  

 

 

DE 

UK 

FR 

FR 

Summary of Contents for DRH 16-5

Page 1: ...Operating instructions Electric air heater Instructions de montage et Mode d emploi R chauffeur d air lectrique ERH 10 04 ERH 12 1 ERH 16 2 ERH 20 2 ERH 25 2 DRH 16 5 DRH 20 5 DRH 25 6 DRH 31 6 www m...

Page 2: ...zelement 6 Anschlussstutzen mit Gummi Lippendichtung P Luftrichtungspfeil T Typenschild Inhaltsverzeichnis 1 Lieferumfang 3 2 Qualifikation Fachinstallateur 3 3 Bestimmungsgem e Verwendung 3 4 Sicherh...

Page 3: ...nder Tragkraft Einbau im waagerechten oder senkrechten Kanal korrektem Anschluss zwischen zwei Rohr leitungen Luftrichtungspfeile beachten korrekter Einbaulage mit Anschlusskasten nach oben oder seitl...

Page 4: ...Verletzungsgefahr Ger tebesch di gung falls das Ger t beim Ein Aus bau Montage Demontage Reinigung Wartung herunterf llt Gewicht bis zu 5 9 kg je nach Type Sorgen Sie bei Montagearbeiten daf r dass Si...

Page 5: ...nden einhalten Bei k rzeren Abst nden geeignete Isolation verwenden Verletzungs Brandgefahr bei nicht ordnungsgem gereinigtem Elektro Lufterhitzer Bei Einsatz eines Luftfilters TFE ist das Ger t wartu...

Page 6: ...tors Luft richtungspfeil auf dem Geh use beachten Wichtige Hinweise Montage nur zul ssig mit Einbaulage Anschlusskasten nach oben oder seitlich Der Anschlusskasten darf nicht nach unten weisen Wenn di...

Page 7: ...ugentlastung sorgen Darauf achten dass diese die Kabelverschraubungen die Leitungen dicht umschlie en Ggf bauseitig abdichten Nicht ben tigte Adern isolieren Geeignetes Befestigungs und Anschluss mate...

Page 8: ...e Entsorgung Das Ger t und auch die Verpackung enth lt wiederverwertbare Stoffe die nicht in den Restm ll gelangen d rfen Entsorgen Sie die Verpackungsmaterialien umweltgerecht nach den in Ihrem Land...

Page 9: ...heater fitted in horizontal or vertical ducting correct connection between two flexible ducts take note of air direction arrows correct installation position with terminal box facing upwards or sidew...

Page 10: ...er the unit When removing and installing the unit support it from below with a hand Danger of injury when working at heights Use appropriate climbing aids ladders Stability should be ensured if necess...

Page 11: ...filter is used the unit is maintenance free Otherwise the unit must be cleaned at regular intervals trained specialist Exercise caution when handling packaging materials Observe applicable safety and...

Page 12: ...es Installation only permissible with terminal box installation location facing upwards or sideways The terminal box may not face downwards If the inflow speed is lower than 1 5 m s the electric air h...

Page 13: ...ons tightly surround the cables If necessary seal on site Insulate any unnecessary cable cores Suitable mounting and connecting material is to be supplied by the customer 1 Switch off mains fuse secur...

Page 14: ...ntally friendly way in compliance with the regulations valid in the country where you are At the end of its service life dispose of the unit in an environmentally friendly way in compliance with the r...

Page 15: ...e Maico ETL ou DTL Le fonctionnement est uniquement autoris aux conditions suivantes Installation fixe sur conduits force por tante suffisante l int rieur d un b timent se monter dans un conduit horiz...

Page 16: ...oduire d objets dans l appareil Risque de br lure d in cendie Garder une distance suffisante par rapport l appa reil lors de son fonctionnement Ne pas couvrir l appareil et ne pas le toucher durant et...

Page 17: ...ement les appareils la tension et la fr quence indiqu es sur la plaque signal tique Effectuer le branchement lectrique conform ment au sch ma de branchement Contr ler le branchement du conducteur PE L...

Page 18: ...idissement appuyer sur le bouton de r initialisation 6 Utilisation mise en marche l arr t Le r chauffeur d air lectrique est utilis avec le syst me optionnel de r gulation de la temp rature ETL ou DTL...

Page 19: ...ventilateur le filtre air les volets p ex ERH 16 2 avec min 320 mm Une distance trop courte peut entra ner un flux d air irr gulier et d clencher la protection contre les surchauffes Utiliser des mat...

Page 20: ...espace de raccordement 3 Veiller la propret de l espace de raccordement et l tanch it du cache de protection qui doit affleurer de tous c t s 12 R gulation La r gulation s effectue par le syst me de r...

Page 21: ...ux d emballage dans le respect de l environnement conform ment aux prescriptions en vigueur dans votre pays liminez l appareil hors d usage dans le respect de l environnement conform ment aux prescrip...

Page 22: ...DE UK FR 18 Schaltbilder Wiring diagrams Sch mas de branchement 22 ERH...

Page 23: ...18 Schaltbilder Wiring diagrams Sch mas de branchement FR UK DE 23 DRH...

Page 24: ...tion Marche K1 Lib ration chauffage US16 ERR Ventilateur centrifuge pour gaine ronde ERM Ventilateur h lico centrifuge pour gaine ronde ESR Ventilateur centrifuge insonoris LW9 Contr leur de d bit d a...