11
ALD 10 T
Insert air filter [13] in connection coupling.
The spacing ring [12] can be used to
close the valve disk to a minimum gap
of 4 mm. The supply air element is
therefore always open.
If the outside air is polluted (if there
is a fire outside for example), the
spacing ring [12] must be removed
and the supply air element fully
closed.
Screw valve disk onto connection coupling.
Undertake basic setting according to
diagram (see page 12)
. Set valve disk
such that the opening gap corresponds to
the volume of air needed.
At temperatures of less than 10 °C
the gap changes by ± 1 mm per 1 °C
(minimum space 4 mm).
5.2 Installation of ALD 12 S,
ALD 12 SVA
Decide on the installation position. If
possible use the right or left in the upper
part of a window.
Drill core hole with 125 mm diameter in
wall.
NOTICE
Ensure an incline of 1...2 % so
that any condensation which
collects can drain outwards.
Cut wall sleeve to thickness of wall.
Insert wall sleeve and seal spaces between
wall sleeve and wall all the way round with
sealant (silicone or acrylic).
For walls on a wooden construction: Also
seal the interface to the wooden
construction. Stick sealing strip [18] on the
wall sleeve in this area.
Screw external grille with attached
fastening material to the outside wall.
For SVA model:
Insert stainless steel protective grille
into wall sleeve until stop is reached.
Cut sound insulating insert to size and
insert in wall sleeve, working from the
inside.
Insert storm protection in sound insulating
insert. Ensure that it is positioned centrally
and stands vertically. The silicone ribs must
not sag under their own weight.
Remove internal cover from connection
coupling and remove transport protection.
Screw connection coupling [20] onto inner
wall Suitable mounting material is to be
supplied by the customer.
Insert air filter in connection coupling.
Use slide to adjust air volume according to
diagram (see page 12)
.
The iris closure opens/closes depending on
the setting.
Move slide to left = CLOSED, move slide
to right = OPEN.
Press internal cover onto connection
coupling until it snaps into place. Ensure
that the unit is open to the top once
installed.
6.
Filter cleaning, filter
replacement
Cleaning interval: six-monthly
Replace air filter every year.
ALD 10
Take off internal cover.
Remove filter holder and air filter from
internal cover.
i
i
i
i
GB
Summary of Contents for ALD 10
Page 2: ...2...