Maico ALD 10 T Mounting Instructions Download Page 13

Mounting 

 UK 

 

13 

6.4 Mounting external grille 

 

1.  Remove cover from external grille. 

 

2.  Secure connection socket [3] to outside 

wall with 4 screws. Suitable mounting 

material is to be supplied by the customer. 

3.  Insert fly screen [2] in connection socket. 

 

4.  Fit external grille cover [1] onto connection 

socket [3] so that it locks into place all 

around. Ensure that the unit is installed 

with the Maico logo in the bottom right. 

5.  Seal external grille [3] to outside wall with 

permanently elastic and weatherproof 

sealant (

 arrows "S"). 

 

Do not seal the underside to allow 

any condensate produced to drain 

away. Suitable sealing material is to 

be supplied by the customer. 

 

6.5 Mounting internal cover/thermo-

valve 

 

ALD 10 

The internal cover is attached to the inside 

wall as follows. 
1.  Take the internal cover [8] off the  

frame [6].  

2.  Stick the sealing strips [5] all around the 

connection socket of frame [6]. 

3.  Push the connection socket of frame [6] 

into the wall sleeve and attach the frame 

to the internal wall. Suitable mounting 

material is to be supplied by the customer. 

4.  Ensure that the air filter unit [7] (inner filter 

holder, air filter and external filter holder)  

is correctly clipped onto the 4 corner 

points of the internal cover [8]. 

5.  Press entire cover unit onto the frame [6], 

until it snaps into place. 

 

Do not impair the slider function 

when mounting. 

6.  Undertake air volume settings according  

to Chapter 7. 

 

ALD 10 T 

 

CAUTION

 

Danger of injury from ten-

sioned spring on thermal 

element of the thermovalve. 

The spring can jump out 

suddenly during dismount-

ting. 

The thermal element is fully 

fitted ex factory. Do not open 

shutter. 

 

1.  Remove cover [12] from connection  

socket [9]. 

2.  Stick the sealing strips [5] all around the 

connection socket [9]. 

3.  Screw connection socket [9] onto inner 

wall Suitable mounting material is to be 

supplied by the customer. 

4.  Insert air filter [11] in connection socket. 

 

The spacing ring [10] can be used to 

close the thermovalve to a minimum 

gap of 3 mm. The supply air element 

is therefore always open. 

 

If the outside air is polluted (if there is 

a fire outside for example), the spa-

cing ring [10] must be removed and 

the supply air element fully closed. 

5.  Screw the cover [12] to the connection 

socket [9]. 

6.  Undertake air volume settings according  

to Chapter 7. 

Summary of Contents for ALD 10 T

Page 1: ...Montageanleitung Au enwand Luftdurchlass Mounting instructions Outside wall air opening ALD 10 ALD 10 T www m aico ventilatoren c om DE UK...

Page 2: ...ang ALD 10 Innenteil Anschlussstutzen G2 Luftfilter 2x Filterhalter und Abdeckung Dichtungsstreifen Wandh lse 2 teilig f r Wandst rken bis 500 mm Au enteil Schutzgitter SG 100 inkl An schlussstutzen F...

Page 3: ...lussstutzen 7 Filterhalter 2x Luftfilter Filterklasse G2 8 Innenabdeckung ALD 10 T 9 Anschlussstutzen innen 10 Distanzring 11 Luftfilter rund Filterklasse G2 12 Abdeckung 3 2 Produktbeschreibung ALD 1...

Page 4: ...ter ALD10 28 m h ALD10 T 24 m h Wandst rke bis 500 mm Kernlochdurchmesser 115 mm Max Umgebungs temperatur 60 C Weitere technische Daten Abmessungen und Kennlinien Kapitel 11 und 12 Internet maico vent...

Page 5: ...der Ver packung nehmen 2 Montageposition festlegen Mindestabstand von 110 mm von der Kernbohrungsmitte zur Wand und Decke nicht unterschreiten 6 3 Montage Wandh lse ACHTUNG Kondenswasser in Richtung...

Page 6: ...lse schieben und den Rahmen an der Innenwand befestigen Geeignetes Befestigungsmaterial ist bauseitig bereit zustellen 4 Sicherstellen dass die Luftfiltereinheit 7 innerer Filterhalter Luftfilter und...

Page 7: ...h Bei Temperaturen unter 10 C ver ndert sich der Spalt um 1 mm pro 1 K Minimalabstand 4 mm 8 Reinigung Filterwechsel F r Artikelnummern der Luftfilter Kapitel 9 Luftfilter T tigkeit G2 Luftfilter Stau...

Page 8: ...hwenningen Deutschland Tel 49 7720 694 445 Fax 49 7720 694 175 E Mail ersatzteilservice maico de 10 Entsorgung Nicht in den Restm ll Der ALD Au enwand Luftdurchlass enth lt teils wiederverwertbare Sto...

Page 9: ...for wall thicknesses up to 500 mm Outer part Protective grille SG 100 incl connection socket fly screen FG 100 Mounting instructions ALD 10 T Internal part Thermovalve with connection socket spacing...

Page 10: ...Connection socket internal 10 Spacing ring 11 Air filter round filter class G2 12 Cover 3 2 Product description ALD 10 Outside wall air opening for nominal size 100 mm With external grille wall sleeve...

Page 11: ...ial pressure and G2 air filter ALD10 28 m h ALD10 T 24 m h Wall thickness up to 500 mm Core hole diameter 115 mm Max ambient temperature 60 C Further technical data Dimensions and characteristic curve...

Page 12: ...packaging 2 Decide on the installation position Ensure a minimum distance of 110 mm between the core hole centre and wall and ceiling 6 3 Mounting wall sleeve NOTICE Condensate will run towards the in...

Page 13: ...pplied by the customer 4 Ensure that the air filter unit 7 inner filter holder air filter and external filter holder is correctly clipped onto the 4 corner points of the internal cover 8 5 Press entir...

Page 14: ...y filter 8 1 Quarterly Check Change the air filter 7 or 11 quarterly as follows 1 Take off the internal cover 8 cover 12 2 ALD 10 Take the filter holder and the air filter out of the connection socket...

Page 15: ...ed and in part substances that must not be disposed of with domestic waste Dispose of the following components in compliance with the regulations valid in your country Packaging materials Air filters...

Page 16: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 technik maico de 03 16_Es 0185 0235 0002_RLF 4_03 16_DSW...

Reviews: