30
BA490801-en
5
Display Codes
Pos: 141 /Technis che Dok umentation/Hebetechnik/COLUMNLI FT/ 490801 RGE/BA/I nhalt: 4908 Display-Codes @ 39\mod_ 1408972336479_75.d ocx @ 2081930 @ @ 1
Display Code LED
Cause
Action
Green
Normal operation, no errors.
Normal operation.
See "Operating Modes;
Automatic Mode, Single Mode and
Group Mode in this manual.
Yellow on
1 or
several
columns
Uncontrolled operation.
Bus line failure.
Replace connecting cable.
CAN bus without terminating resistor.
Check terminating resistors of CAN bus
in dummy plug and power supply unit,
contact service.
CAN controller out of step or
defective.
Turn the main switch off and on again.
If error persists, contact service.
Controller in sleep mode due to short-
circuit of CAN lines.
Replace connecting cable. Contact
service if necessary.
Yellow on
1
column,
Green on
all others
Safety switch triggered.
Carriage has made contact with
obstacle.
Switch column with error message to
single mode. Raise carriage to unlock
the safety wedge or remove obstacle.
Red on
1 column
Thermoswitch triggered.
Overheated motor. Lift stops and
error message appears.
Let the motor cool down. Check
thermoswitch, motor and column.
Acknowledge error with selector button
on control panel.
Red LED will go out and the lift is ready
for operation.
Yellow on
all
columns
Insufficient speed / Overspeed.
Lift stops when irregular motor speed
is detected.
Release control element. The error is
removed and the lift is ready for
operation.
Red on
all
columns
Overloaded lift.
Maximum permissible load exceeded. Lower lift to bottom position.
Acknowledge error with selector button
on control panel.