Emergency-down Function, Mechanical
Pos: 76 /Produktfamilien/Hebetechnik/- Archiv -/00 Hebetechnik Alle/Inhalte/Inhalt: WARNUNG - Manuelles Absenken nur für autorisiertes Personal @ 54\mod_1534924350059_75.docx @ 3081860 @ @ 1
WARNING
Authorised personnel only! Do not restart the lift before the error has been reme-
died.
Pos: 77 /Produktfamilien/Hebetechnik/COLUMNLIFT/490801 RGE/BA/Inhalt: 4908 Manuelles Absenken RGE/RGA @ 26\mod_1325584169425_75.docx @ 1145437 @ @ 1
In case of power failure or defects the lift can be lowered manually.
Once the locking device is in engagement, manual lowering is no longer possible.
The following components are required for manual lowering:
A Lever at brake motor
B
Locking device
1 Pull or shake the safety wedge downward on each column.
2 First push onto the latch using a long screw driver, then additionally push the
manual release lever (in arrow direction).
Intermittently lower the columns in increments of approx. 50 mm, until the lift is
in bottom position.