![MAHA POWERDYNO MSR 1000 Original Operating Instructions Download Page 76](http://html1.mh-extra.com/html/maha/powerdyno-msr-1000/powerdyno-msr-1000_original-operating-instructions_694948076.webp)
76
BA053101-en
Pos: 276 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1.1/ K/Überschrift 1.1.1: Kons tante Ges chw ind igk eit @ 13\m od_1234771175104_ 75.docx @ 339725 @ 3 @ 1
10.1.3
Constant Speed
Pos: 277 /Technis che Dok umentation/ Leis tungsmesstechnik/POWE RDYNO/052301 LPS 3000 R100/BA/Inhalt: 0523 Konstante Ges chw ind igkeit @ 13\m od_1234771607616_ 75.docx @ 339751 @ @ 1
With the operating mode
Constant Speed
the dyno is regulated in such a way that the driving
speed remains constant independent from the traction (from low to full throttle) created by the
vehicle, i.e. only the the speed which was pre-set can be driven. Only the eddy current brake
effectiveness increases up to full throttle but not the speed.
1 Position the vehicle on the dyno and fix it.
2 Call up the menu LOAD SIMULATION and
then the menu point CONSTANT SPEED.
The following screen appears:
3 Enter the target value of the speed
v-target
into the entry box
via the digit keys.
4 Use the button <F8 CONTINUE>.
The measurement screen appears.
The entered speed must be higher than 7 km/h.
5 Start the measurement.
6 Use the button <F6> to start or stop the
graphic recording of the measurement.
Pos: 278 /-----Format- ----/MANUE LLE R UMBRUCH Seitenumbruch @ 0\mod_ 1134403577687_0.docx @ 1277 @ @ 1